  • Page 1 The power behind competitiveness Delta UPS - Amplon Family RT Series, Single Phase 5/ 6/ 8/ 10kVA RT Series, Three Phase 10/ 11/ 15/ 17/ 20kVA Lithium-ion Battery Pack User Manual www.deltapowersolutions.com...
  • Page 2 (“Manual”), including but not limited to the contents, information, and figures are solely owned and reserved by Delta Electronics Inc. (“Delta”). The Manual can only be applied to the operation or the use of this product. Any disposition, duplication, dissemination, reproduction, modification, translation, extraction, or usage of this Manual in whole or in part is prohibited without the prior written permission of Delta.
  • Page 3: Table Of Contents

      Tower Mounting ...................... 14   Chapter 6 : Connection ......................18  Connecting the Delta Lithium-ion Battery Pack (Model: RT-20K-LIB) to its corresponding UPS ..................18   Connecting the Delta Lithium-ion Battery Pack (Model: RT-10K-LIB) to its corresponding UPS ..................20  ...
  • Page 4: Chapter 1 : Product Introduction

    UPS when the main AC source is abnormal. It must be operated in conjunction with a corresponding Delta Amplon RT series UPS as shown in the table below. For its appearance and block diagrams, please refer to the following figures.
  • Page 5 Connector Breaker (Figure 1-3: Block Diagram of RT-10K-LIB)
  • Page 6: Chapter 2 : Important Safety Instructions

    To ensure reliable operation of the battery pack and to protect the battery pack from overheating, these slits and openings must not be blocked or covered. Do not insert any object into the slits and openings that may hinder ventilation. Amplon RT series...
  • Page 7: Standard Compliance

    The two symbols shown above indicate that there is high voltage circuit. Do not open the cover(s) of the Delta lithium-ion battery pack. • The operating temperature of the Delta lithium-ion battery pack is 0°C ~ 45°C (32°F ~ 113°F). 2.2 Standard Compliance •...
  • Page 8: Storage

    • Prior to installation If the Delta lithium-ion battery pack needs to be stored prior to installation, it should be placed in a dry area. The allowable storage temperature and relative humidity (non-condensing) are -15°C ~ +50°C (5°F ~ 122°F) and 5% ~ 95% respectively.
  • Page 9: Chapter 3 : Package List

    The package contains the following items. Please check if any item is missing. If there is anything missing, please contact the dealer immediately. Model: RT-20K-LIB Item Q’ty Delta Lithium-ion Battery Pack 1 PC User Manual 1 PC RS-485 Cable 1 PC...
  • Page 10 Model: RT-10K-LIB Item Q’ty Delta Lithium-ion Battery Pack 1 PC User Manual 1 PC RS-485 Cable 1 PC Ear Bracket Kit 1 SET Tower Stand Extender 4 PCS Battery Cable 1 PC Grounding kit 1 SET NOTE: 1. If there is any damage or anything missing, please immediately contact the dealer from whom you purchased the unit.
  • Page 11: Chapter 4 : Rear Panel

    Chapter 4 : Rear Panel (Figure 4-1: Rear View of RT-20K-LIB) Item Function Connects with the UPS to supply battery power. Pin assignment of the external battery connector is shown as follows. External Batt. Connector The lithium-ion battery pack communicates with the RS-485 Port UPS via the RS-485 port.
  • Page 12 External Batt. Connector The lithium-ion battery pack communicates with the RS-485 Port UPS via the RS-485 port. Breaker Serves as a switch for safety protection. Ventilates the air to avoid overheating. Amplon RT series...
  • Page 13: Chapter 5 : Installation Procedures

    Delta lithium-ion battery pack. See Figure 5-1. (Figure 5-1: Fix the Ear Brackets) 2. Follow the steps ❶ ~ ❸ to install the Delta’s rail kit (optional) onto your rack, and follow the step ❹ to insert the Delta lithium-ion battery pack into the rack.
  • Page 14: Tower Mounting

    Step ❹ : Insert the Delta lithium-ion battery pack into your rack and tighten the provided screws. (Figure 5-2: Insert the Delta Lithium-ion Battery Pack into Your Rack) NOTE: If you want to use a non-Delta rail kit, please only follow step ❹.
  • Page 15 UPS’s package. 2. Pull out the Delta lithium-ion battery pack’s control panel ( ❶ & ❷ ), rotate it 90° clockwise ( ❸ ) and re-insert the control panel ( ❹ ). After that, rotate...
  • Page 16 (Figure 5-4: Rotate the Delta Lithium-ion Battery Pack’s Control Panel & Delta Logo Nameplate) 3. Carefully lift the Delta lithium-ion battery pack upright with the Delta logo and icon on the control panel facing up. At least two people are required. See Figure 5-5.
  • Page 17 4. Fit the Delta lithium-ion battery pack and the UPS into the tower stands. See Figure 5-6. (Figure 5-6: Fit the Delta Lithium-ion Battery Pack and the UPS into the Tower Stands) NOTE: For RT-10K-LIB model, follow the figure below to install the provided grounding kit on the UPS and the Delta lithium-ion battery pack for grounding purpose.
  • Page 18: Chapter 6 : Connection

    UPS, you have to replace the rear panel of the UPS because the rear panel of the UPS is only suitable for the Delta lead-acid battery pack. For the Delta lithium-ion battery pack whose model is RT- 10K-LIB, there is no need to replace its UPS’s rear panel.
  • Page 19 ❶ ❷ ❸ ❹ ❺  ❻ (Figure 6-1: Connect the RT-20K-LIB with the UPS)
  • Page 20: Connecting The Delta Lithium-Ion Battery Pack (Model: Rt-10K-Lib) To Its Corresponding Ups

    6.2 Connecting the Delta Lithium-ion Battery Pack (Model: RT-10K-LIB) to its corresponding UPS Follow the instructions below and the steps ❶ ~ ❷ shown in Figure 6-2 to connect the Delta lithium-ion battery pack (Model: RT-10K-LIB) to its corresponding UPS.
  • Page 21: Chapter 7 : Battery Module Installation & Replacement

    (Figure 7-1: Lithium-ion Battery Module) Follow the instructions below and the steps ❶ ~ ❹ shown in Figure 7-2 to install or replace the lithium-ion battery module in the Delta lithium-ion battery pack. Step ❶ : Unscrew the screws to remove the battery pack’s front panel.
  • Page 22 ❶ ❷     ❸     ❹ (Figure 7-2: Lithium-ion Battery Module Installation or Replacement) Amplon RT series...
  • Page 23 1. To reassemble the battery pack, please perform the steps ❶ ~ ❹ shown above in reverse sequence. 2. If the MBB (Delta Maintenance Bypass Box) is installed behind the Delta lithium-ion battery pack, please keep the MBB away from the Delta lithium-ion battery pack at least 1cm (0.39”).
  • Page 24: Chapter 8 : Operation Procedures

    RS-485 cable, turn on the Delta lithium-ion battery pack’s breaker and the UPS’s input breaker. 3. Follow the Delta Amplon RT Series UPS’s User Manual to turn on the UPS. NOTE : To safely turn off the Delta lithium-ion battery pack after usage, please follow the steps below.
  • Page 25: Chapter 9 : Maintenance

    Chapter 9 : Maintenance It is recommended that you follow the following checklist to ensure the reliability and efficiency of the Delta lithium-ion battery pack. Check the State of Capacity every week via the UPS’s LCD. Check the State of Health (SOH) every 3 months (i.e. perform deep discharge test).
  • Page 26: Appendix 1 : Technical Specifications

    212 x 506 x 76.8 mm module (8.3'' ×19.9'' × 3.0'') Lithium-ion battery pack 13.7 kg 13.7 kg Physical without battery (30.2 lb) (30.2 lb) module Weight Per battery 12.0 kg 12.0 kg module (26.5 lb) (26.5 lb) Amplon RT series...
  • Page 27 Model RT-10K-LIB RT-20K-LIB 0 ~ 3000 m (0 ~ 10000 ft); Operating Altitude 0 ~ 1000 m (0 ~ 3300 ft) (without derating) Environment Operating Temperature 0 ~ 45°C (32 ~ 113°F) Storage Temperature -15 ~ 50°C (-59 ~122°F) Relative Humidity 5 ~ 95% (non-condensing) NOTE: 1.
  • Page 28: Appendix 2 : Warranty

    Seller makes no representation or warranty as to the suitability or fitness of this product for any specific application.             No. : 501327650303 Version : 3.3 Release Date : 2020_12_24 Amplon RT series...
  • Page 31 - Regional Office The United States Australia Delta Electronics (Americas) Ltd. Delta Energy Systems Australia Pty Ltd. 46101 Fremont Blvd. Fremont, CA 94538 Unit 20-21, 45 Normanby Road, Notting Hill VIC 3168, Australia T +1 510 344 2157 T +61 3 9543 3720 E ups.na@deltaww.com...
  • Page 32 5013276503...