F
MULTI
F
MULTI
MAX
Table 305: LMU540HV Heating Capacity Table — Non-Ducted (continued) / Ducted Indoor Units.
Outdoor Air
Combination
Capacity Index
Temp.
(kBtu/h[%])
°F DB °F WB
-4
-4.4
0
-0.4
5
4.5
10
9
17
15
20
19
25
23
Non-Ducted
30
28
Indoor Units
35
32
27 (50%)
40
36
45
41
47
43
50
46
55
51
60
56
63
59
68
64
-4
-4.4
0
-0.4
5
4.5
10
9
17
15
20
19
25
23
Non-Ducted
30
28
Indoor Units
35
32
24 (40%)
40
36
45
41
47
43
50
46
55
51
60
56
63
59
68
64
-4
-4.4
0
-0.4
5
4.5
10
9
17
15
20
19
25
23
Ducted Indoor
30
28
Units
35
32
73 (135%)
40
36
45
41
47
43
50
46
55
51
60
56
63
59
68
64
TC = Total Capacity (kBtu/h).
PI = Power Input (kW).
Nominal Capacity as rated: 0 ft. above sea level with Piping Length as Main Pipe (16.4 ft.) + Branch
pipe (98.4 ft.) = 115 ft.
0 ft. level difference between outdoor and indoor units.
61
64
TC
PI
TC
PI
11.18
1.48
10.34
1.54
13.45
1.53
12.65
1.59
16.15
1.60
15.39
1.66
17.95
1.67
17.23
1.72
19.94
1.75
19.25
1.80
21.14
1.81
20.47
1.86
23.16
1.90
22.47
1.96
25.19
2.01
24.41
2.08
27.23
2.12
26.36
2.19
28.61
2.18
27.81
2.25
30.35
2.26
29.62
2.33
31.04
2.29
30.35
2.36
31.13
2.27
30.51
2.34
31.29
2.25
30.77
2.30
31.44
2.22
31.03
2.27
31.53
2.21
31.19
2.25
31.62
2.20
31.34
2.22
9.94
1.29
9.20
1.34
11.96
1.34
11.25
1.39
14.35
1.40
13.68
1.45
15.96
1.45
15.31
1.50
17.73
1.52
17.11
1.57
18.80
1.57
18.20
1.62
20.59
1.66
19.98
1.71
22.40
1.75
21.70
1.81
24.20
1.84
23.43
1.91
25.44
1.90
24.72
1.96
26.98
1.96
26.33
2.03
27.60
1.99
26.98
2.06
27.68
1.98
27.12
2.04
27.81
1.96
27.35
2.01
27.95
1.94
27.58
1.97
28.03
1.92
27.72
1.96
28.11
1.91
27.86
1.94
28.56
3.71
26.58
3.86
32.68
3.83
30.81
3.98
37.58
3.98
35.84
4.13
40.85
4.12
39.21
4.26
44.46
4.31
42.91
4.44
46.65
4.43
45.16
4.56
50.31
4.65
48.82
4.78
54.02
4.88
52.35
5.05
57.72
5.12
55.88
5.30
60.66
5.27
58.96
5.45
64.34
5.46
62.80
5.64
65.81
5.53
64.34
5.72
66.00
5.50
64.67
5.66
66.33
5.44
65.23
5.57
66.65
5.38
65.78
5.49
66.84
5.35
66.11
5.43
67.04
5.31
66.45
5.38
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
PERFORMANCE DATA
Indoor Air Temp. °F DB
68
70
TC
PI
TC
PI
10.29
1.55
10.17
1.56
12.46
1.62
12.28
1.63
15.03
1.69
14.78
1.71
16.75
1.77
16.46
1.79
18.64
1.86
18.30
1.89
19.79
1.92
19.42
1.96
21.69
2.03
21.28
2.07
23.58
2.14
23.14
2.19
25.46
2.25
25.00
2.30
26.92
2.32
26.46
2.37
28.75
2.40
28.27
2.45
29.48
2.44
29.00
2.48
29.75
2.41
29.32
2.44
30.20
2.36
29.85
2.39
30.65
2.31
30.38
2.33
30.92
2.28
30.70
2.29
31.19
2.25
31.03
2.26
9.15
1.35
9.04
1.36
11.07
1.41
10.92
1.42
13.36
1.48
13.14
1.49
14.89
1.54
14.63
1.56
16.57
1.62
16.27
1.65
17.59
1.68
17.26
1.71
19.28
1.77
18.92
1.81
20.96
1.86
20.57
1.91
22.64
1.96
22.23
2.00
23.93
2.02
23.52
2.06
25.56
2.09
25.13
2.13
26.21
2.12
25.78
2.16
26.45
2.10
26.06
2.13
26.85
2.05
26.54
2.08
27.24
2.01
27.01
2.03
27.48
1.99
27.29
2.00
27.72
1.96
27.58
1.96
26.34
3.90
26.02
3.92
30.29
4.04
29.85
4.07
34.97
4.21
34.40
4.26
38.11
4.37
37.45
4.43
41.56
4.58
40.81
4.66
43.65
4.72
42.84
4.81
47.12
4.96
46.23
5.06
50.55
5.20
49.62
5.32
53.98
5.44
53.01
5.57
57.08
5.61
56.09
5.73
60.95
5.82
59.94
5.92
62.50
5.90
61.48
6.00
63.07
5.83
62.16
5.91
64.02
5.71
63.29
5.77
64.97
5.59
64.42
5.63
65.54
5.51
65.09
5.54
66.12
5.44
65.78
5.46
Nominal heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and
60ºF wet bulb (WB), and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
Heating Capacity Tables
72
75
TC
PI
TC
10.08
1.57
9.63
12.14
1.64
11.63
14.59
1.73
14.00
16.23
1.81
15.59
18.03
1.92
17.34
19.13
1.99
18.40
20.95
2.11
20.16
22.80
2.23
21.96
24.64
2.34
23.75
26.08
2.41
25.14
27.89
2.48
26.88
28.61
2.51
27.57
28.97
2.47
28.00
29.57
2.41
28.70
30.17
2.34
29.40
30.53
2.30
29.83
30.90
2.26
30.25
8.96
1.37
8.56
10.79
1.43
10.33
12.97
1.50
12.45
14.43
1.58
13.86
16.03
1.67
15.41
17.00
1.73
16.36
18.63
1.83
17.93
20.27
1.94
19.52
21.90
2.04
21.11
23.19
2.09
22.35
24.79
2.16
23.89
25.44
2.19
24.51
25.76
2.15
24.89
26.29
2.10
25.51
26.82
2.04
26.14
27.14
2.00
26.51
27.47
1.97
26.89
25.76
3.94
24.62
29.50
4.10
28.26
33.95
4.30
32.58
36.93
4.48
35.48
40.21
4.72
38.66
42.20
4.88
40.59
45.52
5.14
43.81
48.88
5.41
47.08
52.23
5.67
50.35
55.30
5.82
53.30
59.13
6.01
56.98
60.66
6.08
58.46
61.43
5.98
59.35
62.70
5.82
60.84
63.97
5.66
62.33
64.73
5.56
63.23
65.51
5.47
64.14
MULTI F MAX OUTDOOR UNIT | 319
PI
1.63
1.70
1.79
1.87
1.97
2.04
2.16
2.28
2.40
2.47
2.55
2.59
2.54
2.46
2.38
2.33
2.28
1.42
1.48
1.56
1.62
1.72
1.78
1.88
1.99
2.09
2.15
2.23
2.26
2.21
2.14
2.07
2.03
1.99
4.09
4.25
4.44
4.62
4.86
5.01
5.28
5.54
5.81
5.97
6.18
6.26
6.15
5.95
5.75
5.63
5.51
Need help?
Do you have a question about the MULTI F Series and is the answer not in the manual?