LG MULTI F Series Engineering Manual page 18

Multi-zone heat pump systems 1.5 to 4.5 tons
Hide thumbs Also See for MULTI F Series:
Table of Contents

Advertisement

MULTI F OUTDOOR UNIT
General Data
Table 12: Multi F Outdoor Unit Specifications.
Model Number
Rated Cooling Capacity (Btu/h)
Rated Heating Capacity (Btu/h)
Operating Range
Cooling (°F DB)
Heating (°F WB)
Compressor
Inverter Quantity
Oil/Type
Fan (Side Discharge)
Type
Motor Output (W) x Qty.
Motor/Drive
Maximum Air Volume (CFM)
Unit Data
Refrigerant Type
Refrigerant Control/Location
Min. Number Indoor Units/System
Max. Number Indoor Units/System
Maximum Allowable Total Indoor Unit
Connected Capacity (Btu/h)
Sound Pressure (Cooling / Heating) dB(A)
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Power Wiring
(No. x AWG)
4
Heat Exchanger
Material and Fin Coating
Rows/Columns/Fins per inch x Qty.
Piping
Liquid Line Connection (in., OD) x Qty.
Vapor Line Connection (in., OD) x Qty.
Factory Charge lbs. of R410A
Piping Lengths
Maximum Total Piping (ft.)
5
Maximum Outdoor Unit to Indoor Unit Piping (ft)
Piping Length (No Additional Refrigerant [ft])
Maximum Elevation between Outdoor Unit and
Indoor Unit (ft.)
Maximum Elevation between Indoor Unit and
Indoor Unit (ft.)
Rated capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft.
1
of refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units. All
capacities are net with a combination ratio between 95 – 105%.
Rated cooling capacity obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Rated heating capacity obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
At least two indoor units should be connected. For allocated capacity information, see the combination
2
tables on pages 23 to 38.
18 | MULTI F OUTDOOR UNIT
LMU18CHV
1
1
14
Twin Rotary x 1
FVC68D
Propeller
85.4 x 1
EEV/Outdoor Unit
2
2
3
(2 x 28 x 14) x 1
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
LMU24CHV
17,000
22,000
- 118
6
-4 - 64
Twin Rotary x 1
Brushless Digitally Controlled / Direct
1,766
R410A
EEV/Outdoor Unit
2
2
24,000
49 / 52
100
108
3C x 14
Copper Tube/Aluminum Fin and GoldFin™/Hydrophilic
(2 x 28 x 14) x 1
1/4 x 2
3/8 x 2
3.96
164.0
82.0
49.2
49.2
24.6
Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the
3
same in both cooling and heating mode. These values can increase due to ambient conditions during
operation.
All power wiring minimum 3-conductor, stranded, shielded, and must comply with applicable local and
4
national codes. For detailed electrical information, please refer to electric characteristics on page 279.
Piping lengths are equivalent.
5
Installation of an optional Low Ambient Wind Baffle Kit will allow operation down to -4°F in cooling
6
mode.
MULTI
MULTI
LMU36CHV
20,000
24,000
14
- 118
6
-4 - 64
Twin Rotary x 1
FVC68D
Propeller
85.4 x 1
1,766
R410A
EEV/Outdoor Unit
2
3
33,000
49 / 52
100
108
3C x 12
(2 x 38 x 14) x 1
1/4 x 3
3/8 x 3
3.96
246.1
82.0
73.8
49.2
24.6
F
F
MAX
32,000
36,000
14
- 118
6
-4 - 64
FVC68D
Propeller
124.2 x 1
2,119
R410A
2
4
48,000
52 / 55
137
148
3C x 12
1/4 x 4
3/8 x 4
6.18
246.1
82.0
98.4
49.2
24.6