Lorentz PS2-150 Series Manual For Installation And Operation page 28

Solar pumping system
Table of Contents

Advertisement

Available languages

Available languages

26
Controller Installation
7.6.2 Pump Wiring
The motor cables of the pump have a marking to allow
correct wiring. Connect the wires using this sequence:
ƒ 1:
Motor cable L1
ƒ 2:
Motor cable L2
ƒ 3:
Motor cable L3
ƒ
:
Ground connection
If necessary, interchange any two phases to reverse direc-
tion. Refer to chapter "8 Pump Installation" on page 32
for detailed pump installation instructions.