18
Controller Installation
7.2 Controller Elements
ƒ Power on/off switch – The power switch is used to
start or stop the system and as a reset switch. It does not
work as power disconnect switch.
ƒ Indicator Lights – The five LED lights on the front
indicate different operational situations. For a detailed
explanation refer to chapter "10 Operating the Pump"
on page 64.
Table 2: Technical data of the PS2 controller
Model
Pump motor:
rated power
[kW]
PS2-150
0.3
Boost
PS2-150
0.3
PS2-200
0.3
PS2-600
0.7
PS2-1800
1.7
PS2-4000
4.0
Affiliated pump
Max. DC input
motor
voltage
ECDRIVE 150-Boost
ECDRIVE 150-C
ECDRIVE 200-HR
ECDRIVE 600-HR
ECDRIVE 600-C
ECDRIVE 600-CS-F
ECDRIVE 1800-HR
ECDRIVE 1800-C
ECDRIVE 1800-CS-F
ECDRIVE 4000-HR
ECDRIVE 4000-C
ECDRIVE 4000-CS-F
7.3 Technical Data of the Controller
Refer to "Table 2: Technical data of the PS2 controller" on
page 18 for an overview of the most important technical
specifications of the PS controller.
Min. recommended
Vmp
[V]
[V]
50
17
50
17
100
34
150
68
200
102
375
238
Max.output
current
[A]
22
22
11
13
14
14