Trigger Control; Brightness Control; Gain Control - Sony XCD-SX910CR, XCD-SX710CR, XCD-SX910UV, XCD-SX910, XCD-SX710 Technical Manual

Digital video camera module
Hide thumbs Also See for XCD-SX910CR, XCD-SX710CR, XCD-SX910UV, XCD-SX910, XCD-SX710:
Table of Contents

Advertisement

Actual control can be carried out by setting registers
from F0F00800 onward.
ddd indicates the control value expressed as a 12 bit
hexadecimal number.
xxx indicates that any setting made will be ignored.

Brightness control

Address
Data
F0F00800
82000ddd
AE reference control
Address
Data
F0F00804
82000ddd
Shutter (exposure time) control
Address
Data
F0F0081C
82000ddd
83000xxx
C2000xxx
F0F00970
Indicates an
arbitrary value
(See page 25.)
using a 32-bit
floating point
value.

Gain control

Address
Data
F0F00820
82000ddd
83000xxx
Pan/Tilt control
Address
Data
F0F00884
82000ddd
F0F00888
82000xxx
XCD-SX910CR/X710CR
XCD-SX910UV
XCD-SX910/X710
Adjusts the black level.
Sets the AE reference value.
Controls shutter using the manually
set relative value.
Sets to AUTO.
Controls shutter using the absolute
control value.
After F0F0081C has been set to
Absolute value control, set exposure
time using this register.
Sets Gain manually.
Sets Gain to AUTO.
Sets Pan manually.
Sets Tilt manually.

Trigger control

Address
Data
F0F00830
82000000
82010000
82E00000
82E10000
F0F0062C*
80000000
00000000
* These features comply with IIDC v.1.31.
White Balance control (XCD-SX910CR/
X710CR only)
Address
Data
F0F0080C
82bbbrrr
Hue (G Gain) control (XCD-SX910CR/
X710CR only)
Address
Data
F0F00810
82000ddd
Optical Filter control (Bayer pattern
selection) (XCD-SX910CR/X710CR only)
Address
Data
F0F0088C
82000ddd
The following Bayer patterns are available.
Pattern 0
G
B
R G
Pattern 1
B
G
G R
Pattern 2
R
G
G
B
Pattern 3
G
R
B
G
Control
Sets to Hardware Trigger Mode0.
Sets to Hardware Trigger Mode1.
Sets to Software Trigger Mode0. *
Sets to Software Trigger Mode1. *
Outputs a software trigger.
In Trigger Mode0, automatically reset
to 0 when exposure ends.
In Trigger Mode1, ends exposure if
"0" is set.
Sets R and B Gain.
"bbb" sets B Gain, "rrr" sets R Gain.
Sets G Gain.
Selects the Bayer pattern.