HD/VD Output Specifications

HD
VD
The amplitude level is the typical value when
terminated with 10 kΩ. External HD and VD can be
output when you set the HD/VD signal input/output
switch to INT.

VD Input Specifications

5 H – 21 H*
* These VD width values are only effective when high-rate
scan is OFF.
• Input impedance: 75 Ω or 10 kΩ or more.
• Input amplitude 2.0 to 5.0 Vp-p (for both 75 Ω
termination ON and OFF).
• The voltage and pulse width used are as measured at
pin 7 of the 12-pin multi-connector on the rear panel.

HD Input Specifications

2.0 µs – 5.0 µs
• Input impedance: 75 Ω or 10 kΩ or more.
• Input amplitude 2.0 to 5.0 Vp-p (for both 75 Ω
termination ON and OFF)
• The voltage and pulse width used are as measured at
pin 6 of the 12-pin multi-connector on the rear panel.
XC-56BB

Trigger Pulse Specifications

4.5 V
0 V
4.5 V
0 V
• Input impedance: 10 kΩ or more.
• The voltage and pulse width used are measured at pin
9 of the 12-pin multi-connector on the rear panel.
2.0 – 5.0 Vp-p
2.0 – 5.0 Vp-p
2 µs – 1/4 s
Mode Settings
2 – 5.0 V
0 – 0.6 V
9