7.4 Compressor specifications
7.4.1 Reference conditions
Absolute inlet pressure
Relative air humidity
Air inlet temperature
Cooling water inlet temperature
7.4.2 Limitations
Maximum air inlet temperature
Maximum air inlet temperature for hot air version (HAV)
Minimum ambient temperature
Maximum altitude operation
Maximum cooling water temperature at inlet (on ZR)
Maximum cooling water temperature at outlet, open circuit (on ZR)
Maximum cooling water temperature at outlet, closed circuit (on ZR)
Maximum cooling water inlet pressure (on ZR)
7.4.3 Specific data of ZT15 up to ZT22
Nominal working
pressure
Maximum
working
pressure
Maximum
working
pressure, Full-
Feature
Minimum
working
pressure
Installed motor
power
Oil capacity
Sound pressure
level 1)
Sound pressure
level, WorkPlace
Air System 1)
2920 1472 03
Unit
ZT15
ZT15
-7.5
-8.6
bar(e)
7
8
bar(e)
7.5
8.6
bar(e)
7.25
8.35
bar(e)
4.0
4.0
kW
15
15
l
25
25
dB(A)
69
69
dB(A)
65
65
ZT15
ZT18
ZT18
-10
-7.5
-8.6
9.5
7
8
10
7.5
8.6
9.75
7.25
8.35
4.0
4.0
4.0
15
18.5
18.5
25
25
25
69
71
71
65
67
67
bar(a)
1
%
0
°C
20
°C
20
°C
40
°C
50
°C
0
m
1000
°C
40
°C
50
°C
60
bar(e)
7
ZT18
ZT22
ZT22
-10
-7.5
-8.6
9.5
7
8
10
7.5
8.6
9.75
7.25
8.35
4.0
4.0
4.0
18.5
22
22
25
25
25
71
73
73
67
69
69
ZT22
-10
9.5
10
9.75
4.0
22
25
73
69
59