Menu 2 - HOT WATER

2 - HOT WATER
Sub-menus
For the menu
HOT WATER
Status information for the relevant menu can be found
on the display to the right of the menus.
temporary lux
hot water temperature. Status information displays "off"
or what length of time of the temporary temperature in-
crease remains.
comfort mode
information displays what mode is selected, "economy",
"normal" or "luxury".
advanced
Setting periodic increase in the hot water
temperature.
Menu 2.1 - temporary lux
Setting range: 1, 3, 6 and 12 hours, and mode"off"
Default value: "off"
When hot water requirement has temporarily increased
this menu can be used to select an increase in the hot
water temperature to lux mode for a selectable time.
Caution
If comfort mode "luxury" is selected in menu
2.2 no further increase can be carried out.
The function is activated immediately when a time period
is selected and confirmed using the OK button. The time
to the right displays the remaining time at the selected
setting.
When the time has run out SMO 05 returns to the mode
set in menu 2.2.
Select "off" to switch off
Menu 2.2 - comfort mode
Setting range: economy, normal, luxury
Default value: normal
The difference between the selectable modes is the
temperature of the hot tap water. Higher temperature
means that the hot water lasts longer.
24
Chapter 8 |
Control - Menus
2.1 - temporary lux
2.2 - comfort mode
2.9 - advanced
there are several sub-menus.
Activation of temporary increase in the
Setting hot water comfort. The status
temporary lux
.
Overview
2.9.1 - periodic increases
economy: This mode gives less hot water than the other,
but is more economical. This mode can be used in smaller
households with a small hot water requirement.
normal: Normal mode gives a larger amount of hot water
and is suitable for most households.
luxury: Lux mode gives the greatest possible amount of
hot water. In this mode the immersion heater may be
partially used to heat hot water, which may increase op-
erating costs.
Menu 2.9 - advanced
Menu
advanced
has orange text and is intended for the
advanced user. This menu has several sub-menus.
Menu 2.9.1 - periodic increases
period
Setting range: 1 - 90 days
Default value: 14 days
To prevent bacterial growth in the water heater, the
compressor and the immersion heater can increase hot
water temperature at regular intervals.
The length of time between increases can be selected
here. The time can be set between 1 and 90 days. Factory
setting is 14 days. Untick "activated" to switch off the
function.
SMO 05