Danfoss AME 110 NL Datasheet

Danfoss AME 110 NL Datasheet

Actuators for modulating control
Hide thumbs Also See for AME 110 NL:

Advertisement

Actuators for modulating control
AME 110 NL, AME 120 NL

Description

Ordering

SMT/SI
Supply voltage
Type
(V)
AME 110 NL
24 AC
AME 120 NL
Note:
Actuators with 5 m and 10 m cable length are produced on request. Please note this increases lead time.
Spare parts
Length
Type
(m)
5
Cable (24 V)
10
VD.KH.C6.02 © Danfoss 01/2014
The actuators are used together with
automatically balanced combination valve type
AB-QM for DN 10-32.
The actuator can be used with fan coil units,
induction units, small reheaters, recoolers and
zone applications in which hot/cold water is the
controlled medium.
Main data:
• Gap detection at stem up position
• Modulating control
• Force switch-off at stem down position
prevents overload of actuator and valve
• No tools required for mounting
• Maintenance-free lifetime
• Low-noise operation
• Self-positioning process
• Halogen free cables
Speed
Cable length
(s/mm)
(m)
1,5
24
5,0
10
1,5
12
5,0
10
Code No.
082H8052
082H8054
Code No,
Single Pack
Industry Pack
082H8057
082H8067
082H8081
082H8077
082H8098
082H8087
082H8059
/
/
082H8079
/
082H8089
1

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss AME 110 NL

  • Page 1 Data sheet Actuators for modulating control AME 110 NL, AME 120 NL Description The actuators are used together with automatically balanced combination valve type AB-QM for DN 10-32. The actuator can be used with fan coil units, induction units, small reheaters, recoolers and zone applications in which hot/cold water is the controlled medium.
  • Page 2 Data sheet Actuators for modulating control AME 110 NL, AME 120 NL Technical data Type AME 110 NL AME 120 NL Power supply 24 AC; +20 to −15% * running Power consumption standby Frequency 50/60 0-10 (2-10) Ri = 110 kΩ Control input Y 0-20 (4-20) Ri = 500 Ω Closing force...
  • Page 3 Data sheet Actuators for modulating control AME 110 NL, AME 120 NL Installation procedure 1. Check the valve neck. The actuator should be position in stem up position (factory setting). indicator Ensure that the actuator is mounted securely on the valve body 2. Wire the actuator according to the wiring diagram 3.
  • Page 4 Data sheet Actuators for modulating control AME 110 NL, AME 120 NL DIP Switch Setting The actuator has a function selection DIP switch • SW 5: under the removable cover. 0-5/5-10 V - Input signal range in (for service purposes only) sequential mode The switch provides the following functions: If set to OFF position, the actuator is working in the sequential range 0(2)-5(6) V or • SW1:...
  • Page 5 Data sheet Actuators for modulating control AME 110 NL, AME 120 NL Manual override (for service purposes only) Caution: Do not manually operate the ② drive if power is connected! ① Do not dismount the actuator from the valve when it is in a...
  • Page 6 Data sheet Actuators for modulating control AME 110 NL, AME 120 NL VD.KH.C6.02 © Danfoss 01/2014 SMT/SI...
  • Page 7 Data sheet Actuators for modulating control AME 110 NL, AME 120 NL VD.KH.C6.02 © Danfoss 01/2014 SMT/SI...
  • Page 8 Data sheet Actuators for modulating control AME 110 NL, AME 120 NL VD.KH.C6.02 Produced by Danfoss A/S © 01/2014...

This manual is also suitable for:

Ame 120 nl

Table of Contents