Functions; Technical Characteristics Of Optyma; Tm Control, Single-Phase - Danfoss OPTYMA Control AK-RC 101 Operation And Maintenance Manual

Single-phase
Table of Contents

Advertisement

Functions

OPTYMA
Control single-phase:
TM
- Display and adjustment of cold room temperature
setting to 0.1 °C
- Display of evaporator temperature from para-
meter
- System control activation/deactivation
- System warnings (probe/sensor errors, minimum
and maximum temperature warnings, compressor
shutdown)

Technical characteristics of OPTYMA

Power supply
Voltage
Power consumption (electronics only)
Cold room conditions
Operating temperature
Storage temperature
Relative humidity
General characteristics
Type of sensors
Resolution
Sensor read precision
Read range
Digital inputs
Requirements to contact
OPTYMA
Control single-phase - Output characteristics - max. applicable load (230 V AC)
TM
Compressor
Defrost
Fans
Room light
Alarm contact (non-powered contact)
General electrical protection
Dimensions
Dimensions
Insulation / mechanical characteristics
Housing protection rating
Housing material
Type of insulation
OPTYMA
Control single-phase AK-RC 101
TM
- Evaporator fans control
- Automatic and manual defrost (static, heating
element, cycle inversion)
- Direct control of compressor unit up to 2 HP
- Room light, via panel key or door switch
- Alarms/auxiliary relay
- Defrosting, lights and alarms can be operated via
data communication.
Control single-phase
TM
230 V~ ± 10% 50Hz / 60Hz
~ 7 VA
-5 to 50°C
-10 to 70°C
Less than 90% -
Not condensed. No shock influence/vibration.
EKS 221, code no.: 084N3210
0.1 °K
± 0.5 °K
-45...+45 °C
Gold plating
1500W (AC3)
3000W (AC1)
500W (AC3)
800W (AC1)
100W
Automatic fuse 16A
Id=300 mA
Disconnecting power 4.5 kA
168 mm x 97 mm x 262 mm (HxPxL)
IP65
Self-extinguishing ABS
Class II
RS8FD402 © Danfoss A/S 2014/11
7

Advertisement

Table of Contents
loading

Table of Contents