Regulus R2BC 200 Operation Manual

Regulus R2BC 200 Operation Manual

Hot water storage tanks
Hide thumbs Also See for R2BC 200:

Advertisement

Quick Links

www.regulus.eu
EN
Installation and Operation Manual
HOT WATER STORAGE TANKS
R2BC 200, R2BC 300, R2BC 400, R2BC 500, R2BC 750,
R2BC 1000, R2BC 1500, R2BC 2000, R2BC 2500 and R2BC 3000
R2BC 200 - 3000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R2BC 200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Regulus R2BC 200

  • Page 1 Installation and Operation Manual HOT WATER STORAGE TANKS R2BC 200, R2BC 300, R2BC 400, R2BC 500, R2BC 750, R2BC 1000, R2BC 1500, R2BC 2000, R2BC 2500 and R2BC 3000 R2BC 200 - 3000...
  • Page 2: Table Of Contents

    5 Examples of Assigning Connection Points ................... 6 Installation and Commissioning ..................... 7 Tank Insulation ..........................8 Maintenance, Replacement of Magnesium Anode Bar ..............9 Disposal ............................10 Warranty ............................REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 3: Description

    1.3 - Thermal insulation R2BC 200 to 500 tanks are supplied with a hard polyurethane insulation 50 mm thick with a white PVC sur- face. Tanks of 750 and 1000 l volume are supplied with a hard polyurethane insulation 75 mm thick with a white PU leather surface.
  • Page 4: Technical Data And Dimensions Of R2Bc Models

    Max. working pressure - heating coils ........  1 0 bar DHW heating ∆t =35 °C (80/60 - 10/45) - upper coil ..... h DHW heating ∆t =35 °C (80/60 - 10/45) - lower coil ....i REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 5: Operation

    (heat pumps, solar collectors). Hot water temperature should be set to 60-65 °C. This temperature guarantees the best operation and at the same time, it prevents formation of Legionella bacteria. REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 6: Examples Of Assigning Connection Points

    Connections depend on the circuit to be connected, the a.m. examples are informative only. Example I. With a gas boiler and a solar thermal system. gas boiler bb bbb recirculation cold water R2BC REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 7 HEAT PUMP accumulation Table of limit values for total dissolved solids in hot water Description Total dissolved Chlorides solids (TDS) Max. value 6.5 - 9.5 600 mg/l 40 mg/l 100 mg/l 20 mg/l 200 mg/l 0,2 mg/l REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 8: Installation And Commissioning

    In order to prevent water loss, an expansion tank should be installed at the cold water inlet as well (8 l volume for R2BC 200, 12 l volume for R2BC 300 and 400, 18 l volume for R2BC 500, 24 l volume for R2BC 750, 35 l volume for R2BC 1000, 60 l volume for R2BC 1500, 80 l volume for R2BC 2000, 100 l...
  • Page 9: Tank Insulation

    ○ defects caused by mechanical damage to the product, ○ defects caused by tampering or incompetent repair. REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 10: Maintenance, Replacement Of Magnesium Anode Bar

    This product is covered by warranty according to the conditions described in this Manual and according to the Warranty Certificate. A Warranty Certificate is an integral part of the supply. Tank transport or storing in a hori- zontal position is considered a warranty violation! REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 11 REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 12 ©2019 We reserve the right to errors, changes and improvements without prior notice. REGULUS spol. s r.o. E-mail: sales@regulus.eu Web: www.regulus.eu...

Table of Contents