Regulus R2BC 200 Installation And Operation Manual

Regulus R2BC 200 Installation And Operation Manual

Hot water storage tanks
Hide thumbs Also See for R2BC 200:

Advertisement

Quick Links

www.regulus.eu
EN
Installation and Operation Manual EN
HOT WATER STORAGE TANKS
R2BC 200, R2BC 300, R2BC 400, R2BC 500, R2BC 750,
R2BC 1000, R2BC 1500, R2BC 2000, R2BC 2500 and R2BC 3000
R2BC 200 - 3000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R2BC 200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Regulus R2BC 200

  • Page 1 Installation and Operation Manual EN HOT WATER STORAGE TANKS R2BC 200, R2BC 300, R2BC 400, R2BC 500, R2BC 750, R2BC 1000, R2BC 1500, R2BC 2000, R2BC 2500 and R2BC 3000 R2BC 200 - 3000...
  • Page 2: Table Of Contents

    6.4 Connection to water mains ....................6.5 Electronic anode rod installation ..................6.6 Commissioning ......................... 7 Tank Insulation ..........................8 Maintenance, Replacement of Magnesium Anode Bar ............. 9 Disposal ............................10 Warranty ............................REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 3: Description

    1.3 - Thermal insulation R2BC 200 to 500 tanks are supplied with a hard polyurethane insulation 50 mm thick with a white PVC surface. R2BC 750 and 1000 tanks are supplied with a hard polyurethane insulation 75 mm thick with a white PU lea- ther surface.
  • Page 4: Technical Data And Dimensions Of R2Bc Models

    Max. working pressure - heat exchangers ......10 bar DHW heating ∆t =35 °C (80/60 - 10/45) - upper HX ..DHW heating ∆t =35 °C (80/60 - 10/45) - lower HX ..REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 5 G 5/4“ F 268 G 5/4“ F 335 G 5/4“ F 400 G 5/4“ F 400 G 5/4“ F 520 G 5/4“ F 550 G 5/4“ F 640 G 5/4“ F 640 G 5/4“ F 1640 REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 6: Typical Installation Example

    5 - Typical Installation Example With a boiler and solar thermal system REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 7: Installation And Commissioning

    In order to prevent water loss, an expansion vessel should be installed at the cold water inlet as well (8 l volume for R2BC 200, 12 l volume for R2BC 300 and 400, 18 l volume for R2BC 500, 24 l volume for R2BC 750, 35 l volume for R2BC 1000, 60 l volume for R2BC 1500, 80 l volume for R2BC 2000, 100 l volume for R2BC 2500 and 2×60 l volume for R2BC 3000).
  • Page 8: Commissioning

    Set the heating controller in compliance with the documentation and ma- nufacturer’s recommendations. Check regularly a proper function of all control and adjusting elements. REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 9: Tank Insulation

    If damage to a tank occurs due to neglected substitution of a magnesium anode rod or a non-working electro- nic anode, warranty cannot be claimed. REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 10: Maintenance, Replacement Of Magnesium Anode Bar

    This product is covered by warranty according to the conditions described in this Manual and according to the Warranty Certificate. A Warranty Certificate is an integral part of the supply. Tank transport or storing in a hori- zontal position is considered a warranty violation! REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 11 REGULUS - R2BC Hot Water Storage Tanks - www.regulus.eu │...
  • Page 12 ©2022 We reserve the right to errors, changes and improvements without prior notice. REGULUS spol. s r.o. E-mail: sales@regulus.eu Web: www.regulus.eu...