Valve Set Up; Operation - Uwatec X-Black Manual

Bcs
Table of Contents

Advertisement

8. VAlVE SET UP

SCUBAPRO BCs are completed by the BPI System (Balance Power Inflator).
The BPI, connected to the tank/regulator, makes it possible to control buoyancy in the water
(inflation/deflation of the BC) by using inflate and deflate buttons.
Alternatively, users can assemble the AIR2 system.
Connecting the BPI and/or AIR 2
The Power Inflation Valve allows you to inflate
your BC using air from your SCUBA cylinder.
Its LP hose, threaded on a LP port of the first
stage regulator, is connected to the Power
Inflation Valve by the Quick Disconnect
Coupling that works with the air on or off.
To attach the Quick Disconnect Coupling
(fig. 6 - C):
1. Make sure that both fittings are free of contamination prior to mating them together.
2. Pull back the collar of the Quick Disconnect Coupling, while pushing the hose firmly
onto the fitting plug found on the power inflation valve.
3. Release the collar when the coupling is fully seated on the plug. Pull gently but firmly on
the hose to check for a secure connection.
4. To disconnect, pull the Quick Disconnect Coupling collar back and disengage the LP
hose from the plug.
! WARnInG
Keep water out of the inflatable aircell of the BC. Repeated use of the oral valve
or the Overpressure Valve may allow water inside the BC, reducing the amount of
buoyancy provided by the BC. This could result in injury or death. Drain all water out
of the BC prior to every use.

9. OPERATIOn

Inflating the BC with the Power Inflation Valve (on BPI and/or AIR2)
To inflate the BC, press the Power Inflation Valve Button (fig. 6-P). Air should enter the BC.
For better control during inflation use short bursts of air by repeatedly pressing and releasing
the PIV button.
Inflating the BC with the Oral Valve (on BPI and/or AIR 2)
The Oral Valve is found on the end of the airway. It allows you to inflate your BC with your
exhaled breath. Use of this valve for inflation is recommended on the surface, or on land
prior to diving. It may be used when you cannot, or do not wish to add air to the BC with
the Power Inflation Valve.
1. First exhale a small amount of air into the mouthpiece of the valve to purge any water
that may be trapped there.
2. With the same breath, continue to exhale while deeply depressing the Oral Inflation
Valve Button (fig. 6 - O).
3. Release the Oral Valve Button when you inhale fresh air.
4. Repeat steps 2 and 3 until the desired amount of buoyancy is reached.
C
C
P
P
O
O
A.I.R. 2
fig. 6
C
P
O
B.P.I.
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents