Operating Instructions Tray washing machine Modell BTA 160 / 240
Maintenance
PLEASE NOTE:
5. Clean water rinse system
Check the complete system for damage and watertightness
Check nozzles for cleanliness
Check water quantity (use the water meter or measure manually)
Check float switch function
6. Drying
Fan
Check fan for exterior damage
Check current consumption (IN see wiring diagram)
Check fan for quiet running (bearing damage) (visual and noise check)
Check suction side grid for cleanliness
Blowing box
Check fan system nozzles for damage.
Function check
The suction side temperature must not exceed
Check internal drying chamber for cleanliness
Clean internal drying chamber with hot water (remove greases and oils)
see later
x1
7. Heat recovery
Exhaust fan
Check fan for exterior damage
Check current consumption (IN see wiring diagram)
Check fan for bearing noise (damage to bearing)
Check protection grid for cleanliness
Heat exchanger
Check heat exchanger for cleanliness
Clean heat exchanger with hot water
Check heat exchanger watertightness
Datei:BA_BTA_9668415_EN_2009-10.docx
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
Whenever any electrical components are disconnected and reconnected,
replaced or repaired, a safety test must be conducted, at least on these
components!!!
°C.
x1

W e reserv e the right to change execution and construction!

Service step
At least once
Cleaning
quarterly
works
Daily
9668415
At least once
At least once
or twice a
yearly
year
but
but
Every
Every
2000 h
1000 h
42/48