AccuTemp EVOLUTION Series Installation & Operator's Manual page 5

Table of Contents

Advertisement

9. Is the correct NEMA Plug and Receptacle being used on the supply power cord?(Tick Box)
Type of NEMA Plug
L6-30P (208/240V 6kW)
L15-30P (208/240V 10kW)
15-50P (208/240V 15kW)
Connected (Auto-fill) Models Only
10. Is the supply water pressure lower than 30PSI (Tick Box)
11. With the Steam Collector Pan removed and the Steam Chamber empty, does the Auto-
Fill Water Stream hit the chamber floor half-way to three-quarters of the way towards the
opposite wall?
Note: The Auto-Fill Valve has a maximum water supply pressure of 60 psi. If stream goes beyond ¾ or IF water
pressure gauge is > 60 psi, THEN install water regulator.
12. Is the chamber water level at (or just below) the stamped water line on inside left chamber
wall after auto fill has been completed? (Tick Box)
13. Is the Float Ball Installed in the unit? (Tick Box)
14. Is there a High Water alarm when the Float Ball is removed? (Tick Box)
All Models (Connected & Connection-less)
15. Does the Low Water Light and Alarm turn OFF once the chamber water level has reached the
middle of the Low Water Sensor? (Connected Water Models will only have the Low Water
Light and no Alarm. Tick Box.)
16. Has additional piping been added to the steam vent? (Tick Box)
Reference Page 12 for guidance.
17. Verify the water temperature in COOK MODE (COO on digital display)
18. Does the unit cycle the heat once it is in COOK MODE? (Tick Box)
19. Is there any added drain hose/piping attached to the Steamer Drain System? Note: Does the
added drain hose/piping to the steamer meet the specifications listed on the instruction label
attached to the back of the steamer? (Tick Box)
20. If unit is part of a double stack, does the top steamer have a drain kit installed?
(If NO, Warranty is void until kit is installed. Tick Box).
21. Take photographs of install, including: Front of steamer, Side view of steamer, hook up and
supply. (Tick Box)
I accept this Start-up form as complete and accurate:
Signed:
Print Name:
MP4010-1903
EVOLUTION Steamer Start-Up Form (continued)
Tick One
Restaurant Management
ACCUTEMP PRODUCTS INC.
4815 N CLINTON PARK DR - FORT WAYNE - IN - 46825
TELEPHONE: 800-480-0415, SERVICE@ACCUTEMP.NET
PRINTED IN USA
L16-20P (480V 14kW)
IEC 60309-2 (230/415V)
Date:
YES
Tick One
YES
YES
°F
/
/
NO
NO
NO