3.7 Electrical Requirements and Notices
The electrical voltage requirement is listed on the data plate that is located on the lower left side panel.
All AccuTemp Evolution Electric Steamers are supplied with a power cord and plug that must be connected to the
specified receptacle, see below for reference.
Make sure the voltage is within 10% of the voltage listed on the steamer data plate.
Connection to any other voltage not identified on the data plate will cause damage to the components and is not covered under
warranty.
Grounding provides a path for electric current to reduce risk of shock.
This product is equipped with a power cord having a grounding plug. If plug is removed or hard wired, UL approval is lost.
The plug must be plugged into a receptacle that is properly installed and grounded in accordance with all National, State and
local electrical codes or in the absence of local electrical codes with the National Electric Code, ANSI/NFPA 70, or the Canadian
Code, CSA C22.2 as applicable.
Under no circumstances shall the plugs grounding prong be cut or bent to fit a receptacle other than the one specified.
Do not use any adapters.
Any in-field modification made that bypass the safety features of this appliance will result in serious injury or death. DO NOT
DIRECT WIRE THIS APPLIANCE.
Any in-field modifications made without written authorization from AccuTemp Products, Inc. will void all written and oral
warranties.
ELECTRICAL SPECIFICATIONS
CONNECTED
Model #
E62081E060
Volts AC
208
Phase
1
Amps
29
Breaker Size
30 amp
Watts (kW)
6
NEMA Plug
L6-30P
CONNECTIONLESS
Model #
E62081D060
Volts AC
Phase
Amps
Breaker Size
16.23"
Watts (kW)
[412mm]
NEMA Plug
16.70 R
MP4010-1903
Steamer Model "E" Specifications
E62083E100
E62083E150
208
208
3
3
28
42
30 amp
50 amp
10
15
L15-30P
15-50P
Notes:
1. Allow 3" between fryer, ranges, and other hot surfaces.
2. 5' power cord supplied with single or 3 phase.
3. For use on individual branch circuit only.
4. Do not connect to a circuit operating at more than 150V to ground.
Steamer Model "D" Specifications
5. Dimensions outside brackets are inches, in brackets are millimeters.
E62083D100
E62083D150
6. Each unit equipped with 3/4" male garden hose connector
7. Each unit equipped with 3/4" barbed drain line connector
208
208
208
8. DO NOT plumb a single drain line between the 2 units. Each
1
3
3
unit must have a separate drain line.
29
28
42
30 amp
30 amp
50 amp
6
10
15
41.15"
[1045mm]
L6-30P
L15-30P
15-50P
Notes:
1. Allow 3" between fryer, ranges, and other hot surfaces.
2. 5' power cord supplied with single or 3 phase.
E6 T
6 Pan, Electric Boiler-free Convection
Countertop Steamer
E62301E070
E62401E060
E62403E110
230
240
208
1
1
3
32
25
22
50 amp
30 amp
30 amp
7
6
8
IEC 60309-2
L6-30P
L15-30P
220/250V
E62401D060
E62403D110
E62403D130
240
208
240
1
3
25
22
26
30 amp
30 amp
6
8
11
L6-30P
L15-30P
C
E
ABLETOP
ONNECTED
VOLUTION
E62403E130
E64155E110
240
240
380 400 41 5
3
5
26
32
14
14
15
50 amp
20 amp
11
13
9
10
11
15-50P
IEC 60309-2
E6 T
C
220/380-240/415V
ABLETOP
ONNECTIONLESS
6 Pan, Electric Boiler-free Convection
Connectionless Countertop Steamer
E62301D070
E64155D110
240
230
380 400 41 5
3
1
5
32
32
14
14
50 amp
50 amp
20 amp
13
7
9
10
15-50P
IEC 60309-2
IEC 60309-2
220/250V
220/380-240/415V
E64803E140
440
480
3
16
17
20 amp
12
14
L16-20P
E
VOLUTION
E64803D140
440
480
3
15
16
17
20 amp
11
12
14
L16-20P
10