Installation Manual I Service and Troubleshooting

5. Troubleshooting

5.1 Steamer Will Not Power On
Verify that the steamer is plugged into the proper outlet.
Verify the the external breaker is on.
If the 'High Water' warning light is on open the drain valve to drain the water until the light goes
out.
Verify that the float ball is in place.
5.2 Steamer Will Not Fill with Water
Ensure water supply to unit is turned on.
Clean two water sensors in cooking cabinet
5.3 Steamer is Overfilling with Water (Connected)
Ensure unit is level.
Clean two water sensors in cooking cabinet.
5.4 Steamer Does Not Heat
If the operators display doesn't light up, see Section 5.1.
Verify the steamer door is closed, as the unit will not heat when the door is open.
5.5 Steam Comes Out of Door (Overpressure)
Verify that the door is completely closed and latched.
Wait a minute to see if it stops. After the steamer refills with water it is normal for some steam to
come out the door for a brief amount of time, usually less that one minute.
5.6 Steamer Temperature is Low
When the steamer automatically refills the fresh water, the temperature of the steamer will drop.
The steamer should reheat quickly.
If -99F or -1F appears call AccuTemp for assistance.
If frozen product is added the temperature will take time to recover.
5.7 Food is Undercooked
Verify that the door is completely closed and latched.
Opening and closing the door frequently can lower the temeperature and increase cook times.
Verify the steam vent is clear of debris.
Call AccuTemp for assistance with recipe timing.
If these don't solve your problem contact our Technical Service Department.