Installation Manual I Service and Troubleshooting
5. Troubleshooting
5.1 Steamer Will Not Power On
•
Verify that the steamer is plugged into the proper outlet.
•
Verify the the external breaker is on.
•
If the 'High Water' warning light is on open the drain valve to drain the water until the light goes
out.
•
Verify that the float ball is in place.
5.2 Steamer Will Not Fill with Water
•
Ensure water supply to unit is turned on.
•
Clean two water sensors in cooking cabinet
5.3 Steamer is Overfilling with Water (Connected)
•
Ensure unit is level.
•
Clean two water sensors in cooking cabinet.
5.4 Steamer Does Not Heat
•
If the operators display doesn't light up, see Section 5.1.
•
Verify the steamer door is closed, as the unit will not heat when the door is open.
5.5 Steam Comes Out of Door (Overpressure)
•
Verify that the door is completely closed and latched.
•
Wait a minute to see if it stops. After the steamer refills with water it is normal for some steam to
come out the door for a brief amount of time, usually less that one minute.
5.6 Steamer Temperature is Low
•
When the steamer automatically refills the fresh water, the temperature of the steamer will drop.
The steamer should reheat quickly.
•
If -99F or -1F appears call AccuTemp for assistance.
•
If frozen product is added the temperature will take time to recover.
5.7 Food is Undercooked
•
Verify that the door is completely closed and latched.
•
Opening and closing the door frequently can lower the temeperature and increase cook times.
•
Verify the steam vent is clear of debris.
•
Call AccuTemp for assistance with recipe timing.
If these don't solve your problem contact our Technical Service Department.
•
•
•
•
MP4010-1903
Hours: 7AM - 7PM EST 7 Days a Week (excluding certain Holidays)
Phone - 800.480.0415 or 260.469.3040
Email - service@accutemp.net
Web site - www.accutemp.net
21