Installation of indoor unit
Step two: Wiring of indoor unit
1. Remove the left and right support plate.
electric box is in the left of the unit,
press the screw at the electric box cover,
take off the electric box cover.
2. Take out the electric box cover, screw down
the test wire of screw,take out the test wire
from the cable cross hole.
3. Thread the power connection wire thr-
ough the cable cross hole from the cable
cross hole.
4. Well connect the wire according to wi-
ring diagram. (see figure on the right)
5. Fix the protecting cover section of po-
wer connection wire at the groove of
wire clamp and then screw up the fix-
ing screw to fix the connection wire
firmly.
Note:
Please contact the maintenance center for another connection wire with adequate
length if the present one is not long enough.
● Correctly connect the wires.
● Well screw up the screws fixing terminals and connection wirings.
● The wirings should be properly fixed.
● Incorrect wiring connection of grounding wire may lead to electric shock.
● Well fix the electric box cover with sufficient screw. Improper assembly of electric
box cover may cause fire hazard or electric shock.
● For the air conditioner without plug, an circuit break must be installed in the line.
The circuit break should be all-pole parting and the contact parting distance
should be more than 3mm.
● All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
screw
cable cross hole
blue
black
brown
wire clamp
connecting cable
37
wiring board
test wire
wiring board
3
brown
blue
yellow/green
(black)
wire clamp
power cord