Cutout Switch - HE-VA AC-LITE User Manual

Auto-controller
Table of Contents

Advertisement

Figure 5
The default speed sensor calibration factor (SSF) programmed in the head unit =
'7.78' (millimeters/pulse). This is theoretically correct for the radar sensor when it is
installed at exactly the specified angle to the ground. Often though, the sensor may
not be exactly at the prescribed angle. It is therefore recommended that to ensure
accurate speed measurement, you check the calibration value by performing an
'Autocal' procedure (please refer to section 4.4).

2.5 Cutout switch

The implement-mounted cutout finger switch enables the system to automatically start
and stop operation as the implement is lifted and lowered.
It therefore needs to be mounted in a suitable position to operate as the implement
enters work.
NOTE: For fitting instructions please refer to the separate instruction leaflet
ref. S/DC/500-10-121 provided.
1
Brown (+V)
2
Blue (0V)
3
Yellow/Green (Sig)
HE-VA Auto-Controller AC-Lite - May 2016
9