Labrie Pendpac WITTKE RETRO FL Maintenance Manual page 94

Hide thumbs Also See for Pendpac WITTKE RETRO FL:
Table of Contents

Advertisement

84 Maintenance
Figure 3-23
Distances to achieve
2.
Adjust the tab so it activates the arm fully retracted proximity switch.
3.
Lower the arms.
4.
Retract the forks until a distance of 31 inches is achieved between both fork cylinder attachments
(center to center) [see Figure 3-23, (B)].
5.
Adjust the tab so it activates the fork fully retracted proximity switch.
6.
Perform tests to see if the warning lamp on the MDM control module reacts properly and the
"Arm not Stowed" message appears on the monitor when the forks or the arms are not fully
parked.
7.
If the warning lamp does not "react" properly on the MDM control module or the "Arm not
Stowed" message does not appear on the monitor, readjust the proximity switches and their tabs.
The warning lamp should turn off only when the arms are fully raised and the forks fully
retracted.
31"
B
57-3/8"
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents