Table 6
Hydraulic system (cont'd)
Item
Description
119
Clean the breather cap (replace if
necessary) [more often if required]
120
Clean suction strainer with varsol/
compressed air (replace if damaged)
[more often if required]
To protect the hydraulic components of your new equipment, the return line filter MUST BE
CHANGED AFTER THE FIRST 50 HOURS OF USE. Thereupon, the filter should be changed once
every 1,000 hours or following a major hydraulic component failure.
121
Change hydraulic return line oil filter
(more often if required)
122
Clean magnetic plug (more often if
required)
Pump
123
Inspect pump for leaks
124
Ensure pump is securely mounted
125
Ensure driveline is securely mounted
Hydraulic valve bank
126
Inspect valve bank for leaks
127
Ensure valve bank is securely mounted
128
Check system pressure relief valve(s)
settings. Adjust if required. [Use
pressure gauge. Record.]
c
*129
Check arms down pressure relief valve
settings. Adjust if required. (Use
pressure gauge. Record.)
*130
Check cart tipper pressure relief valve
settings. Adjust if required. (Use
pressure gauge. Record.)
Miscellaneous
131
Inspect all hydraulic lines for leaks,
chafing
132
Inspect all hydraulic cylinders and misc.
hydraulic components for leaks
Pre-
At
Daily
Weekly
trip
landfill
O
O
O
O
O
O
Maintenance 57
1000
Monthly
hours
M
M
M (new unit)
M
M
M
M
M
M
M
M
M
M
M
M