Pid-Ssc; Querying Related Information - Huawei SmartLogger1000 User Manual

Hide thumbs Also See for SmartLogger1000:
Table of Contents

Advertisement

SmartLogger1000
User Manual
Figure 7-31 Setting running parameters
Parameter
Operation mode
Commissioning
output voltage
Repair time
Voltage to be
repaired

7.8.8 PID-SSC

7.8.8.1 Querying Related Information

Choose Monitoring > PID-SSC and query related information on the displayed page.
Figure 7-32 Querying PID-SSC-related information
Issue 12 (2019-01-15)
Description
Specifies the current working mode of the PID module.
Before setting this parameter to Commissioning, ensure that
inverters in a PV array are powered off and their DC switches are
turned off. This working mode is used during commissioning
after deployment or fault locating. In this case, the PID-PVBOX
delivers the output voltage based on the value of the
commissioned output voltage.
Set this parameter to Normal after ensuring that the PID module
works normally.
Specifies the output voltage when the PID module works in
commissioning mode.
Set the recovery time for each day.
Specifies the output voltage when the PID module works in normal
mode.