Description Of Structure-Borne Noise - Man L23/30DF Project Manual

Power plant, four-stroke genset
Table of Contents

Advertisement

MAN Diesel & Turbo
1671754-6.2
Page 1 (1)
L28/32S, L23/30DF, L28/32S-DF, L27/38S, L23/30S, L21/31S, L16/24S, L28/32DF,
Introduction
This paper describes typical structure-borne noise
levels from standard resiliently mounted MAN Gen-
Sets. The levels can be used in the project phase
as a reasonable basis for decisions concerning
damping and insulation in buildings, engine rooms
and surroundings in order to avoid noise and vibra-
tion problems.
References
References and guidelines according to ISO 9611
and ISO 11689.
Operating condition
Levels are valid for standard resilient mounted Gen-
Sets on flexible rubber support of 55° sh (A) on rela-
tively stiff and well-supported foundations.
Frequency range
The levels are valid in the frequency range 31.5 Hz
to 4 kHz.
Figure 1: Structure-borne noise on resiliently mounted GenSets
2016.02.22

Description of structure-borne noise

V28/32H, V28/32S, L16/24, L21/31, L23/30H, L27/38, L28/32H
D 10 25 0