Vibration Limits And Measurements - Man L23/30DF Project Manual

Power plant, four-stroke genset
Table of Contents

Advertisement

MAN Diesel & Turbo
3700395-8.3
Page 1 (2)
L23/30DF, L28/32S-DF, L28/32S, L27/38S, L23/30S, L21/31S, L16/24S, L28/32DF,
GenSet
Measure-
Description
ment
point
1
TC fore
2
Governor/TC
aft
3
Front support
4
Aft support
Engine: VDI 2063T
Alternator: ISO 8528-9, DIN 6280-11
Note: All measurements are specified as mm/s r.m.s.
Date
2017.12.14

Vibration limits and measurements

V28/32H, V28/32S, L16/24, L21/31, L23/30H, L27/38, L28/32H
Limit
Measure-
Description
ment
point
18
5
Aft
bearing
18
6
Alternator
cooler
18
7
Intermediate
bearing
18
8
Alternator foot
Running
Load
Hours
%
100
100
100
Limit
Measure-
ment
point
alternator
18
9
25
10
18
11
See
12
below *
* Alternator
P ≤ 1250 kVA
P >1250 kVA
Value 1 or 2 are depending on alternator make
Vertical (z)
1
2
3
4
5
Crosswise (y)
Longitudinal (x)
D 10 24 0
Description
Limit
Alternator foot
See
below *
Automation box
25
A-side
Automation box
25
B-side
T&P panel
25
Value 1
Value 2
20
24
18
22
6
7
8
9
10 11 12

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Man L23/30DF