Compressed Air System - Man L23/30DF Project Manual

Power plant, four-stroke genset
Table of Contents

Advertisement

MAN Diesel & Turbo
3700205-5.1
Page 1 (2)

Compressed air system

Figure 1: Diagram for 10 bar compressed air system (for guidance only, please see the plant specific engine diagram)
Air supply!
Air supply must not be interrupted when engine
is running
Pipe description
Pipe description
K1
Compressed air inlet
Table 1: Flange connections are standard according to DIN 2501
General
The compressed air system on the engine consists
of a starting system, starting control system and
safety system. Further, the system supplies air to
the jet system and the stop cylinders on each fuel
2015.11.09 - Tier II, Stationary, Low pressure, Standard
Compressed air system
injection pump. On 8 and 9 cylinder engines air is
supplied to the oil mist detector through a reduction
valve.
The compressed air is supplied from the starting air
receivers (30 bar) through a reduction station,
where from compressed air at 10 bar is supplied to
the engine. The reduction station should be located
as near the starting air receiver as possible.
To avoid dirt particles in the internal system, a
strainer equipped with a drain valve is mounted in
the inlet line to the engine.
Starting system
The engine is started by means of a built-on air
DN 50
starter, which is a turbine motor with gear box,
safety clutch and drive shaft with pinion. Further,
there is a main starting valve.
Control system
The air starter is activated electrically with a pneu-
matic 3/2-way solenoid valve. The valve can be
activated manually from the starting box on the
engine, and it can be arranged for remote control,
manual or automatic.
B 14 00 0
L27/38S, L27/38

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Man L23/30DF

Table of Contents