Fuel Oil Filter Duplex - Man L23/30DF Project Manual

Power plant, four-stroke genset
Table of Contents

Advertisement

MAN Diesel & Turbo
1679744-6.7
Page 1 (1)

Fuel oil filter duplex

DN25
DN32
DN40
DN50
DN65
DN25
DN32
DN40
DN50
DN65
DN25
DN32
DN40
DN50
DN65
Table 1: Fuel oil filter duplex
To safeguard the injection system components on
the GenSets, is it recommended to install a fuel oil
filter duplex, as close as possible to each GenSet.
The fuel oil filter duplex is with star-pleated filter ele-
ments. The fuel oil filter duplex is supplied loose and
it is recommended to install it, as close as possible
to each GenSet, in the external fuel oil supply line.
GenSets with conventional fuel injection system or
common rail fuel system must have fuel oil filter
duplex with a fineness of max. 25 microns (sphere
passing mesh) installed as close as possible to
each GenSet.
The filter surface load of the 25 microns filters must
not exceed 1.5 l/cm² per hour !
2015.11.27
Fuel oil filter duplex
L27/38S, L21/31S, L16/24S, V28/32S, L16/24, L21/31, L27/38
Fuel oil filter duplex - Star-pleated element
25 microns (400/40) (sphere passing mesh)
HFO
12-18 cSt
litres/h
1000
1500
2800
3500
5800
652
1000
1844
2337
3885
Pressure drop (bar)
0.018
0.016
0.019
0.016
0.015
Figure 1: Fuel oil filter duplex.
MDO
2.5-14 cSt
litres/h
1000
1500
2800
3500
5800
Filter area (cm
)
2
652
1000
1844
2337
3885
0.016
0.015
0.018
0.014
0.013
E 11 08 1
MGO
1.5-6 cSt
litres/h
1000
1500
2800
3500
5800
652
1000
1844
2337
3885
0.013
0.012
0.015
0.012
0.011

Hide quick links: