3.3.10
RED, GREEN, BLUE GAIN(Range 0~80, MWCP default value is 40. But
monitor's default value is different as current source. So if you want to know
current value, you have to read single set value)
-
-
-
These functions are used to adjust color only factory line or service. Don't open to normal user.
These functions are used to adjust picture Red/Green/Blue gain of scaler.
3.3.11
BACKLIGHT(Range 0~100, Default value = 72)
Same format as COLOR BRIGHTNESS SETTING.
but send cmd is "BLU", "BLD", "BLT" and return cmd is "BLT=".
3.3.12
COLOR TONE RED(Range 0~100, Default value = 50)
Same format as COLOR BRIGHTNESS SETTING.
but send cmd is "URU", "URD", "URE" and return cmd is "URE=".
3.3.13
COLOR TONE GREEN(Range 0~100, Default value = 50)
Same format as COLOR BRIGHTNESS SETTING.
but send cmd is "UGU", "UGD", "UGR" and return cmd is "UGR=".
3.3.14
COLOR TONE BLUE(Range 0~100, Default value = 50)
Same format as COLOR BRIGHTNESS SETTING.
but send cmd is "UBU", "UBD", "UBL" and return cmd is "UBL=".
3.3.15
SAVE COLOR
This function is for saving current Brightness , Contrast and Backlight setting value of selected
one monitor.
RS232 Protocol NSL-4601
RED GAIN
Same format as COLOR BRIGHTNESS SETTING.
but send cmd is "RGU", "RGD", "RGN" and return cmd is "RGN=".
GREEN GAIN
Same format as COLOR BRIGHTNESS SETTING.
but send cmd is "GGU", "GGD", "GGN" and return cmd is "GGN=".
BLUE GAIN
Same format as COLOR BRIGHTNESS SETTING.
but send cmd is "BGU", "BGD", "BGN" and return cmd is "BGN=".
39 of 58