5.1.2 Electric connection

DANGER! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid specification
should be compared with that of the device (see rating plate).
Connect the device only in case of compliance!
Before connecting the device make sure that the voltage and frequency values on
the rating plate are consistent with the existing electric installation.
The allowable voltage deviation is ±10%.
Connect the device to the electric installation according to the valid international,
national, and local regulations.
The device is equipped with the electric cable of type H07RN-F 5G2.5 CE14
without the plug.
The device must be connected to the potential levelling circuit (ground).
The connection terminal is located under the left side of the device at sign
.