Commands To Get Rcp Status Information - Sony CNA-1 Technical Manual

Camera control network adaptor
Hide thumbs Also See for CNA-1:
Table of Contents

Advertisement

Receive:
"6d,8b,26,fe,0c,01,00,01,02,00,00,03,00,00,04,00,0
1,05,00,00,06,00,00,07,00,00,08,00,00,09,00,00,0a,
00,00,0b,00,00,0c,00,00\n"
Reply from Master is:
There are 12 Cameras.
Camera No.1 and No.4 are available, and others are not
available.

Commands to get RCP status information

Get RCP number range info
"
Type
Request
6d,4c,02,fe,12\n
Reply
6d,8c,06,fe,12,00,[RCP No. Min],00,[RCP No.
Max]\n
Parameters:
RCP No. Min:
Minimal value of RCP number, "01"-"60"
(1-96 in Decimal)
RCP No. Max:
Maximal value of RCP number, "01"-
"60" (1-96 in Decimal)
Example:
Send: "6d,4c,02,fe,12\n"
Receive: "6d,8c,06,fe,12,00,01,00,0c\n"
Reply from Master is:
Available RCP on the CNS has the number in range from
1 to 12.
Get RCP status info
"
Type
Request
6d,4d,[DLEN],fe,12,[NUM],(00,[RCP No.])...\n
Reply
6d,8d,[DLEN],fe,12,[NUM],(00,[RCP
No.],fe,[CAM No.],[RCP Status])...\n
Parameters:
DLEN:
Data length after "[DLEN]"
"fe,12":
Fixed value. No other value is permitted.
NUM:
Number of parameters on this
command.
when Request, this means number of
"00,
[RCP No.]", range is "01"-"19" (1-25 in
Decimal)
when Reply, this means number of
"00,[RCP No.],fe,[CAM No.],[RCP
Status]"
"00":
Fixed value. No other value is permitted.
RCP No.:
"01"-"60" (1-96 in Decimal)
"fe":
Fixed value. No other value is permitted.
CAM No.:
Camera to which RCP is assigned, "01"-
"60" (1-96 in Decimal), "00"=None
RCP status:
Status is presented by bit info.
bit 1: 0 = Assignment is default,
1 = Assignment has been changed
bit 0: 0 = not Available, 1 = Available
RCP is recognized as available when it
is turned on and is connected to the
CNS.
Format
Format
Example:
1. Request status of RCP No.1.
Send: "6d,4d,05,fe,12,01,00,01\n"
Receive: "6d,8d,08,fe,12,01,00,01,fe,01,01\n"
Reply from Master is:
RCP No.1 is assigned to Camera No.1, its assignment is
default and it is available.
2. Request status of RCP No.1 and RCP No.4.
Send: "6d,4d,07,fe,12,02,00,01,00,04\n"
Receive:
"6d,8d,0d,fe,12,02,00,01,fe,01,01,00,04,fe,01,03\n"
Reply from Master is:
RCP No.1 is assigned to Camera No.1, its assignment is
default and it is available.
RCP No.4 is assigned to Camera No.1, its assignment
has been changed and it is available.
Get Available RCP status info list
"
Type
Request
6d,4e,02,fe,12\n
Reply
6d,8e,[DLEN],fe,12,[NUM],(00,[RCP
No.],fe,[CAM No.],[RCP Status])...\n
Parameters:
DLEN:
Data length after "[DLEN]"
"fe,12":
Fixed value. No other value is permitted.
NUM:
Number of parameters on this
command.
when Reply, this means number of "00,
[RCP No.],fe,[CAM No.],[RCP Status]"
"00":
Fixed value. No other value is permitted.
RCP No.:
"01"-"60" (1-96 in Decimal)
"fe":
Fixed value. No other value is permitted.
CAM No.:
Camera to which RCP is assigned, "01"-
"60"
(1-96 in Decimal), "00"=None
RCP status:
Status is presented by bit info.
bit 1: 0 = Assignment is default,
1 = Assignment has been changed
bit 0: 0 = not Available, 1 = Available
RCP is recognized as available when it
is turned on and is connected to the
CNS.
Example:
Send: "6d,4e,02,fe,12\n"
Receive:
"6d,8e,0d,fe,12,02,00,01,fe,01,01,00,04,fe,01,03\n"
Reply from Master is:
There are two RCP available in the CNS, the number of
which is 1 and 4.
RCP No.1 is assigned to Camera No.1, its assignment is
default and it is available.
RCP No.4 is assigned to Camera No.1, its assignment
has been changed and it is available.
Get All RCP status info list
"
Type
Request
6d,4f,02,fe,12\n
Reply
6d,8f,[DLEN],fe,12,[NUM],(00,[RCP
No.],fe,[CAM No.],[RCP Status])...\n
Extended commands of Optional Software
Format
Format
21