Main Scan Magnification
Sub-Scan Magnification
1. Place the OS-A3 test chart on the exposure glass and make a copy from one of the feed stations.
2. Check the magnification ratio. If necessary, adjust the magnification with the following SP mode.
Sub-scan magnification
Standard White Density Adjustment
This procedure adjusts the standard white density level. Do this adjustment after you do any of the following:
• After you replace the standard white plate.
• After you replace the NVRAM on the BICU. (But note that you do not need to carry out this adjustment
if you have replaced the BICU itself but retained the previous NVRAM board [by moving it over onto
the new BICU].)
• After you perform a memory all clear (SP 5801 2)
Procedure:
1. Place 10 sheets of new A4/LTR paper (sideways, LEF) or new A3/DLT paper on the exposure glass,
and close the platen cover or the ADF.
2. Enter SP 4428 1 and select "1: YES". The machine automatically adjusts the standard white density.

ADF Image Adjustment

A: Leading edge registration
SP mode
SP 4009
SP mode
SP 4008
Copy Adjustments Printing/Scanning
Specification
± 1.0%
Specification
± 1.0%
4