Tenma 72-10395 Manual

Tenma 72-10395 Manual

Pocket size digital multimeter
Hide thumbs Also See for 72-10395:

Advertisement

Pocket Size Digital Multimeter
Model: 72-10395
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 72-10395 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tenma 72-10395

  • Page 1 Pocket Size Digital Multimeter Model: 72-10395...
  • Page 2 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This digital multimeter is designed and manufactured in accordance with IEC61010, double insulation, CAT II 600V overvoltage and pollution grade 2 safety standard. Please operate according to this manual, otherwise the protection provided by the device will be impaired or fail.
  • Page 3 OPERATING PARAMETERS • Ambient temperature: 23 ± 5 ºC ºC. • Relative humidity: ≤75% • Auto power off - the meter will enter the standby mode if there is no operation of the range selector and buttons within 30 minutes. In standby mode it can be re- activated by pressing any button or turning the range selector.
  • Page 4 OPERATION DC voltage measurement (See Figure 2) • Turn the range selector to DC V, Auto and DC icons appear on the LCD. • Connect the black test probe to the cathode of the power to be measured and the red test probe to the anode of the power to be measured.
  • Page 5 Resistance measurement (See Figure 4) • Turn the range selector to • Connect test probes in parallel to the resistance to be measured; • Read measured results on the display. Notes: • To avoid meter damage, when making in-circuit measurements make sure the circuit power is turned off and all capacitance has been discharged before measurement.
  • Page 6 Diode and continuity measurement (See dotted part in Figure 6) • Turn the range selector to • Press SELECT button to access diode mode (press it again to switch to continuity test). • If connect test probes to the diode to be measured (with black test probe to cathode and red test probe to anode), then the reading on LCD will be an approximate value of diode forward voltage drop...
  • Page 7 GENERAL SPECIFICATIONS Accuracy ± (a% Input Function Range Description olution readings Protection +b digits) ± (0.8%+1) 600V DC Input impedance 10mV Voltage 600V AC ≥10MΩ 400V 100mV (DC V) 600V ± (1%+3) Input impedance 10mV ≥10MΩ; ± (1.2%+3) Frequency response: 400V 100mV 600V DC...
  • Page 8 INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT These symbols indicate that separate collection of Waste Electrical and Electronic Equipment (WEEE) or waste batteries is required. Do not dispose of these items with general household waste. Separate for the treatment, recovery and recycling of the materials used. Waste batteries can be returned to any waste battery recycling point which are provided by most battery retailers.