YASKAWA SI-ET3 Technical Manual page 51

Ac drive option
Hide thumbs Also See for SI-ET3:
Table of Contents

Advertisement

Byte
Command
39
SEL_MON 5/6
40
41
Reference selected with
SEL_REF3
42
43
44
45
Reference selected with
SEL_REF4
46
47
48
49
Reference selected with
SEL_REF5
50
51
52
53
Reference selected with
SEL_REF6
54
55
56
Reserved (0)
63
Byte
Command
32
INV_IO (51H)
33
34
SUB_STAT
35
36
SEL_REF 3/4
37
SEL_REF 5/6
38
SEL_MON 3/4
39
SEL_MON 5/6
40
41
Monitor data set to
SEL_MON3
42
43
44
45
Monitor data set to
SEL_MON4
46
47
48
49
Monitor data set to
SEL_MON5
50
51
52
53
Monitor data set to
SEL_MON6
54
55
56
Reserved (0)
63
YASKAWA ELECTRIC SIEP C730600 88E YASKAWA AC Drive Option SI-ET3 Technical Manual
INV_IO Command
Use the SEL MON5/6 command to select the contents of MON5 with bits 0 to 3 and to select the
contents of MON6 with bits 4 to 7.
Refer to
Table 22
for the selection ranges for SEL REF5/6 and SEL MON5/6.
Reference selected with SEL_REF3 (Lower)
Reference selected with SEL_REF3 (Upper)
Not used (Ignored if a value is set.)
Not used (Ignored if a value is set.)
Reference selected with SEL_REF4 (Lower)
Reference selected with SEL_REF4 (Upper)
Not used (Set to 0.)
Not used (Set to 0.)
Reference selected with SEL_REF5 (Lower)
Reference selected with SEL_REF5 (Upper)
Not used (Set to 0.)
Not used (Set to 0.)
Reference selected with SEL_REF6 (Lower)
Reference selected with SEL_REF6 (Upper)
Not used (Set to 0.)
Not used (Set to 0.)
Not used
INV_IO Response
Command code
Refer to
SUB_STAT (Sub-Command Status) on page
The value set in the command.
The value set in the command.
The value set in the command.
The value set in the command.
Monitor data set to SEL_MON3 (Lower)
Monitor data set to SEL_MON3 (Upper)
Not used (Set to 0.)
Not used (Set to 0.)
Monitor data set to SEL_MON4 (Lower)
Monitor data set to SEL_MON4 (Upper)
Not used (Set to 0.)
Not used (Set to 0.)
Monitor data set to SEL_MON5 (Lower)
Monitor data set to SEL_MON5 (Upper)
Not used (Set to 0.)
Not used (Set to 0.)
Monitor data set to SEL_MON6 (Lower)
Monitor data set to SEL_MON6 (Upper)
Not used (Set to 0.)
Not used (Set to 0.)
Not used
Description
Description
47.
10 Sub-Commands