Maintenance and Upgrade
Figure 47: Remove the Fan Module
Step 4
To replace a fan module, hold the fan module in front of the fan slot.
Step 5
Push the fan module into the chassis until it is properly seated and the latches snap into place.
If the system is powered on, listen for the fans. You should immediately hear the fans operating. If you do not hear the
fans, make sure the fan module is inserted completely into the chassis and the faceplate is flush with the outside surface
of the chassis.
Step 6
Verify that the fan is operational by checking the fan module LED. See
of the fan LEDs.

Remove and Replace the SSD

Take note of the following warnings:
Warning
Statement 60—UL- and CSA-Certified Equipment Warning
This card is intended to be installed in UL- and CSA-certified equipment in the field by the user in the
manufacturer's defined operator access area. Check the equipment manufacturer to verify/confirm that your
equipment is suitable for user-installed application cards.
Warning
Statement 1029—Blank Faceplates and Cover Panels
Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages
and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other
equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all
cards, faceplates, front covers, and rear covers are in place.
Front Panel LEDs, on page 7
Cisco Firepower 4110, 4120, 4140, and 4150 Hardware Installation Guide
Remove and Replace the SSD
for a description
59