Install the FIPS Opacity Shield
Figure 44: Attach the FIPS Opacity Shield to the Cable Management Brackets
1
FIPS opacity shield
Cable management bracket
3
Step 8
Attach the 15 TELs. For information on the procedure and correct placement of the TELs, see the Tamper Evidence
Label (TEL) Placement section (section 2.13 ) in the
document.
Step 9
Attach the power cable to the chassis and connect it to an electrical outlet.
Step 10
Press the power switch on the rear panel.
Step 11
Check the power LED on the front panel. See
green indicates that the chassis is powered on.
Note
When you toggle the power switch from ON to OFF, it takes several seconds for the system to power down.
Do not remove the power cable until the power LED is off. After removing power from the chassis either by
moving the power switch to OFF or unplugging the power cord, wait at least 10 seconds before turning power
back ON.
Step 12
See the quick start guide for your operating software for further configuration information:
Cisco ASA for Firepower 4100 Quick Start Guide
Cisco Firepower 4110, 4120, 4140, and 4150 Hardware Installation Guide