Fisher & Paykel HD30 Installation Instructions Manual page 19

Hide thumbs Also See for HD30:
Table of Contents

Advertisement

Fig.19
Downdraft Unit Remote Blower Electrical Connection
• Connect the power supply cable into the box as described in the 'Downdraft unit internal blower
electrical connection' section (above).
• To use a remote blower, install a control cable between the downdraft unit and the remote blower. See
the 'Remote blower electrical connection' on next page.
• Additional knock outs should be used for the remote blower wiring.
• Install a suitable UL listed strain relief or conduit fitting (not included) into the knock out.
• Connect the remote blower wiring into the downdraft unit: N (neutral) into the right terminal, L1 (live)
into the left terminal and the green (ground) wire goes into the ground terminal Fig.20.
• Ensure that the terminal screws are tightly holding all wires in place.
• The remote blower will be connected to the additional control cable
• Replace the cover of the terminal box Fig.18.
https://producthelp.fisherpaykel.com/us/Cook/Ventilation/Downdraft/HD36/User_Guide_HD36/05_installation_instructions
Fig.20
Updated: Fri, 28 Jun 2019 03:30:59 GMT
Powered by
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd36

Table of Contents