6. Prepare for Electrical Connection
Downdraft Unit
• Remove the cover of the terminal box from the downdraft unit Fig.14.
• Decide whether the power source should enter the downdraft unit from below or from the back and
remove the respective knock out. Install a UL listed strain relief or conduit fitting (not included) in the
knock out Fig.15.
• If the downdraft unit is being installed with a remote blower, remove the knock out for the control cable.
• With the assistance of another person, lift the downdraft unit into the prepared cutout in the cabinet. The
over counter mounting brackets should rest on the countertop.
• Secure the downdraft unit to the floor and countertop with screws into the previously drilled holes Fig.16.
• Push the end caps into place on the downdraft unit on top of the counter and lock them in place Fig.17.