Removable Input Modules

Input Modules:
Four types of input modules are available: DVI-D, 3G-SDI,
The
DVI-D
input module accepts DVI signals up to 1920 x 1200 progressive at 60Hz.
The
3G-SDI
input module accepts SDI signals up to 1920 x 1080 progressive at 60Hz.
The
VGA
input module accepts analog signals up to 1920 x 1200 progressive at 60Hz.
The
S-Video / Composite
Any one of the input modules shown below may be installed in the card slot.
VGA Module Switches
Function
Switch 1
RGBS
On
YPbPr
Off
VGA
On
SOG
Off
OSM / RS-232
Off

Module Removal and Installation

The ScaleOR must be turned off prior to installing or replacing the input module.
Input Module Removal:
Use a number 1 Phillips screwdriver to loosen, but not remove, the screws located on the left and right
sides of the module's mounting plate. When the screws are clear of the chassis, remove the module by
gripping the screws and pulling the module out.
Installation:
Slide the new module into the chassis until it contacts the connector, then push gently until the module
seats. The module is correctly seated when its mounting plate is flush with the chassis's back panel. Thread
the module's screws into the chassis until they touch the mounting plate, then tighten each screw by
turning it another quarter turn.
input module accepts S-Video / Composite NTSC or PAL signals .
DVI-D
VGA
Switch 2
Switch 3
On
Off
On
Off
Off
Off
Off
Off
Off
On
VGA
and
S-Video / Composite
S-Video / Composite
1. To select the
Input Format
Serial
control switch 3
is On switches 1 and 2 are disabled.
2. To select the input format manually turn switch 3
Off. Then, using the table to the left, set switches 1
and 2 to the format of the input signal.
3G-SDI
using the
OSM
must
be On. When switch 3
or via
6