ScaleOR™ Video Scaling System USER MANUAL ENGLISH...
Page 3
Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. NDS provides this information as reference only. Reference to products from other vendors does not imply any recommendation or endorsement.
Tab 5 Startup ----------------------------------------------------- 8 Tab 6 Control ----------------------------------------------------- 9 Menu Overview ----------------------------------------- 9 ScaleOR Setup ----------------------------------------- 10 DVI and SDI Picture Menu ----------------------- 10 VGA, RGBS, YPbPr, and SOG Menu ------------ 11 Color Menu------------------------------------------- 12 Setup Menu ------------------------------------------ 13...
Warnings and Cautions This symbol alerts the user that important information regarding the installation and / or operation of this equipment follows. Information preceded by this symbol should be read carefully in order to avoid damaging the equipment. This symbol warns user that un-insulated voltage within the unit may have sufficient magnitude to cause electrical shock.
NDS neither assumes nor authorizes any person to assume for it any other liabilities in conjunction with and/or related to the sale and/or use of its products. To ensure proper use, handling and care of NDS products, customers should consult the product specific literature, instruction manual, and/or labeling included with the product or otherwise available.
About This Manual This manual is designed to assist the user with installation, setup and operation of the ScaleOR and its associated displays. A list of displays that may be used with the ScaleOR is in the Compatible Displays section under General Information on the following page.
4). General Information Installation: ScaleOR units may be stacked on a equipment carrier, a surgical cart or mounted in a standard 19” rack. Ensure that the air vents are not blocked. Power Supply: The provided power supply, Ault and SL Power Electronic Corp Model: MENB1030A1200C02 12VDC, includes 4 interchangeable wall plug adapters.
The illustration shows the switch in its ON state. When the ScaleOR is turned on the blue ring flashes at the rate of 5 flashes per second for 15 seconds then, becomes steady if a video signal is detected. If a...
1280x1024/60.02 SXGA 1280x1024/75.02 SXGA 1280x1024/85.02 SXGA 1360X768/60.01WXGA 1366X768/59.79 WXGA 1440X900/59.89 WXGA 1600X1200/60 UXGA 1680X1050/59.95 WSXGA 1920x1200/50 WUXGA 1920x1200/60 WUXGA Use Menu * Note: To set the output mode from the ScaleOR’s OSM, all switches must be set to Off .
Power Supply and Wall Adapters The power supply is shown with the US wall adapter installed. To exchange the adapter, proceed as follows: Place the power supply on your work surface as shown. Press and hold the button labeled PUSH. Twist the adapter 1/8 turn toward the OPEN arrow, and lift it off the power supply.
OSM / RS-232 Module Removal and Installation The ScaleOR must be turned off prior to installing or replacing the input module. Input Module Removal: Use a number 1 Phillips screwdriver to loosen, but not remove, the screws located on the left and right sides of the module’s mounting plate.
ScaleOR’s input is displayed on the monitor. If the ScaleOR has been turned on for more than 15 seconds and a video signal is not detected the blue ring is will flash at the rate of 1 flash per second.
Control A 4 button keypad, located below and to the right of the ScaleOR logo, allows the user to make adjustments to various ScaleOR parameters using the On Screen Menu (OSM) system. Menu System Overview Press the MENU button once to open the OSM. The input and output resolution are shown at the top of the menu.
ScaleOR Setup DVI and SDI Picture Menu Sharpness: Press fi or fl to adjust the sharpness (focus) of the displayed image. Scaling (Graphics): This parameter is enabled when the input signal is not 16:9, not interlaced, and not 480P or 576P.
Select using fi or fl buttons. SmartSync™ / Alternative Modes On initialization NDS’ proprietary SmartSync technology examines the incoming signal and automatically displays the video image in its proper format. To run SmartSync highlight the SmartSync / Alternative Modes parameter and press the fi button.
Color Menu Brightness: Press the fi or fl button to adjust brightness. Contrast: Press the fi or fl button to adjust contrast. Red, Green, Blue: Press the fi or fl button to increase or decrease the intensity of the selected color. Saturation (Video): This parameter is enabled only when the input is 16:9, 480P, 576P, or interlaced.
Notes: 1. This parameter is not available when a DVI or 3G - SDI input module is installed in the ScaleOR. 2. If this parameter is “grayed” out when the VGA module is installed, then the VGA module has been preconfigured to accept only the format that appears in blue.
Modes Menu The available output modes are shown when the Modes tab is selected. If the Modes tab is selected using the fl button, the tab’s legend changes to Modes 0-15 and modes 0 through 15 are displayed. Pressing the fl button a second time, changes the tab’s legend to Modes 16-31 and modes 16 through 31 are displayed.
To restore the Factory Defaults turn the ScaleOR off, press and hold the MENU button. While holding the MENU button, turn the unit on. After approximately 10 seconds the “Restoring Factory Defaults” message appears on the monitor connected to the ScaleOR.
Serial Port Setup and Test Hardware Setup Turn the ScaleOR on. Connect your PC to the ScaleOR using a USB to Mini 5 USB (NDS P/N 35Z0047) or equivalent cable. Device Manager Open the PC’s Device Manager, and select Ports (COM & LPT). Find the USB Serial Port (COMx) entry.
Wall socket: Some wall sockets have on / off switches built in. If the socket you are using has a built in switch, verify that is in the on position. Mitigation: Bypass the ScaleOR by connecting the output of the video source directly to a monitor. Confidence test...
Connectors and Pin Outs Input Connectors DVI Input and Output Connectors DVI-D* Digital only. 1 RED 6 GND RED 11 N. C. * Compliant with DVI 1.0 2 GREEN 7 GND GREEN 12 DDC_SDA 3 BLUE 8 GND BLUE 13 HORIZ SYNC PIN# SIGNAL PIN# SIGNAL 4 N.C.
Operating Altitude 2,000 m (6,600 ft) Storage Temperature -20 to +50 C (-4 to +122 Storage Humidity 5 to 85% RH Storage Altitude 10,000 m (33,000 ft) Notes: a. Specifications are subject to change without notice. Contact NDS for recent specifications.
SDI Supported Resolutions DVI Supported Resolutions Horizontal Vertical Vertical Horizontal Vertical Vertical Signal Parameter Supported Range Resolution Resolution Frequency Resolution Resolution Frequency Active Resolution 640 x 480 min to 1920 x 1200 max (pixels) (lines) (Hz) (pixels) (lines) (Hz) (Horizontal x Vertical 480i 29.97 1280...
Ethanol 80 % by volume Unacceptable solvents: MEK (Methyl Ethyl Ketone) Toluene Acetone Note: The acceptable cleaning and disinfecting materials listed above have been tested on NDS products and, when used as directed, do not harm the product’s finish and or its plastic components.
Electromagnetic Compatibility (EMC) Tables All medical electronic devices must conform to the requirements of IEC 60601-1-2. Precautions, adherences to the EMC guideline information provided in this manual and verification of all medical devices in simultaneous operation are required to ensure the electromagnetic compatibility and co- existence of all other medical devices prior to a surgical procedure.
Page 31
EMC Tables Guidance and manufacturer’s declaration – electromagnetic emissions The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Emissions Compliance Electromagnetic environment-- guidance The product uses RF energy only for its internal function.
Page 32
EMC Tables Guidance and manufacturer’s declaration – electromagnetic immunity The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment –...
Page 33
EMC Tables Recommended separation distances between portable and mobile RF communications equipment and the product The product is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the product can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the product as recommended below, according to the maximum output power of the communications equipment.
+81 3 5753 2466 info@ndssi.jp Oriental Media Center Suite 2302, Tower C No.4, Guang Hua Road Chao Yang District Beijing, 100026 China +86 10 8559 7859 info@ndssi.com.cn NDS Quality System ISO 9001:2008 and ISO 13485:2003 FDA Registration #2954921 60G0541 Rev F...