  • Page 1 Smart-in DC/AC POWER CONVERTER SM-Series SP-Series User Manual...
  • Page 2: Table Of Contents

    SUMMARY: 1. INTRODUCTION 2. MODELS 3. IMPORTANT SAFETY INSTRUCTIONS 4. PROTECTION FEATURES 5. MODE OF OPERATION 6. INDICATIONS 7. INTERFERENCE PROBLEMS 8. BATTERY REQUIREMENTS 9. INVERTER MOUNTING 9.1 INSTALLATION STEPS 9.2 AC LOADS CONNECTION STEPS 10. RATED VS. ACTUAL CURRENT OF LOADS 11.
  • Page 3: Introduction

    1. INTRODUCTION: Smart-in is the new range of inverters designed and developed by NDS, which has managed to create a series of professional products that reflect their own customers expectations. These Inverters have been designed to guarantee the best performance in terms of safety, efficiency and reliability.
  • Page 4: Models

    2. MODELS: Smart-in Power Inverter range consists of the following models: Smart-in SM: OUTPUT Input Voltage Input Voltage POWER code: code: 400W SM-400 SM400-24 600W SM-600 SM600-24 1000W SM-1000 SM1000-24 1500W SM-1500 SM1500-24 Smart-in SP: OUTPUT Input Voltage Input Voltage POWER code: code:...
  • Page 5: Important Safety Instructions

    3. IMPORTANT SAFETY INSTRUCTIONS: This chapter contains important safety and installation instructions for Smart-in SM and SP series power inverters. WARNING! Pay attention to handle this device. Read this manual before installation and use Device for use in enclosed spaces protected from rain and splashes of water and liquids in general.
  • Page 6 – Do not cover or obstruct the air intake vent openings and/or install in a zero- clearance – Do not work in the vicinity of lead-acid batteries. Batteries generate corrosive gases during normal operation that can damage the inverter. This gas is also explosive, so it is can be very dangerous.
  • Page 7: Protection Features

    4. PROTECTION FEATURES: Our Power inverters are equipped with numerous protection features to guarantee safe and trouble-free operation: ✔ Soft Start ✔ Protection against overload and shortcircuit ✔ Low battery alarm ✔ Protection against polarity inversion and overtemperature Alerts you if the battery has become discharged to Low Battery Alarm 10.5V or 21V.
  • Page 8: Mode Of Operation

    5. MODE OF OPERATION: Inside the Smart-in inverterS there are 2 main circuit stages, to convert the DC input voltage to the output AC voltage: 1) First stage consistes of an isolated high frequency DC/DC converter to convert the input 12V DC (or 24V, according to the version) to an higher voltage up to 330V DC.
  • Page 9: Indications

    6. INDICATIONS: LED Indicators Green and Red: The Green LED is ON when Inverter is switched ON and it is operational The Red LED is ON only to show an alarm condition (Over Load, Over Heat etc...) Main Switch with 3 positions: 0 –...
  • Page 10: Interference Problems

    7. INTERFERENCE PROBLEMS: Some inexpensive stereo systems may emit a buzzing noise from their loudspeakers when operated from the inverter. This occurs because the power supply in the audio system does not adequately filter the modified sine wave produced by the inverter. The only solution is to use a sound system that has a high quality power supply, or use a pure sine wave inverter.
  • Page 11: Battery Requirements

    8. BATTERY REQUIREMENTS: Battery type and battery size strongly affect the performance of the power inverter. Therefore, you need to identify the type of loads your inverter will be powering and how much you will be using them between charges. To determine the minimum battery size that you need to operate appliances, follow these steps: •...
  • Page 12: Installation Steps

    9. MOUNTING THE INVERTER: The inverter has four slots in its mounting bracket that allow the unit to be fastened against a bulkhead, floor, wall or other flat surface. Ideally, the mounting surface should be cool to the touch. It is more electrically efficient to use longer AC wiring than DC wiring, so install the inverter as close as possible to the 12V/24V DC power source.
  • Page 13: Rated Vs. Actual Current Of Loads

    • Turn the appliance on. • Plug in additional appliances and turn them on. Notes: 1. Plug the cord from the AC appliances you wish to operate into the AC receptacle. When turn ON the inverter the Red and Green LEDs both lit for 3~5seconds then the red LED not lit, the green LED indicator lights to indicate that the inverter is functioning.
  • Page 14: Fuses Replacement

    Normally after you replace the new fuse, the inverter restart automatically. Sometimes it is possible that there are additional faults for which it is necessary to contact the service of NDS. OPTIONALS: –...
  • Page 15: Technical Characteristics

    13. TECHNICAL CHARACTERISTICS: Smart-in Modified SM-400 SM400-24 Continuous output power 400W 400W Peak output power 800W (few seconds) 800W (few seconds) Output voltage (RMS) 110V or 230V 110V or 230V Output frequency 50 or 60 Hz ± 3 Hz 50 or 60 Hz ± 3 Hz Usb output 5V @ 2.1A 5V @ 2.1A...
  • Page 16 Smart-in Pure SP-400 SP400-24 Continuous output power 400W 400W Peak output power 1000W (few seconds) 1000W (few seconds) Output voltage (RMS) 110V or 230V 110V or 230V Output frequency 50 or 60 Hz ± 3 Hz 50 or 60 Hz ± 3 Hz Usb output 5V @ 2.1A 5V @ 2.1A...
  • Page 17: Warranty

    Any dispute will be under the competent jurisdiction of the court of Pescara (Italy) Mod..........Serial n..........Purchase date ........Stamp and signature of the seller NDS ENERGY S.r.l. Via G. Pascoli, 169 65010 Cappelle sul Tavo (PE) Italy MANUALE UTENTE...
  • Page 18 SOMMARIO: 1. INTRODUZIONE 2. MODELLI 3. IMPORTANTI ISTRUZIONI DI SICUREZZA 4. PROTEZIONI 5. FUNZIONAMENTO 6. INDICATORI 7. POSSIBILI INTERFERENZE 8. REQUISITI DELLE BATTERIE 9. MONTAGGIO DELL'INVERTER 9.1 PROCEDURA DI INSTALLAZIONE 9.2 PROCEDURA DI ALIMENTAZIONE DELLE UTENZE AC 10. CORRENTE ASSORBITA E DICHIARATA DELLE UTENZE AC 11.
  • Page 19: Modelli

    Smart-in è la nuova gamma di Inverter progettata e sviluppata da NDS, che ha portato alla nascita di una serie di prodotti professionali che ripecchiano le aspettative dei propri clienti. Questi dispositivi sono stati progettati per garantire le migliori prestazioni in termini di sicurezza, efficienza e durata.
  • Page 20: Importanti Istruzioni Di Sicurezza

    Le due linee Smart-in Power Inverter si componegono dei seguenti modelli: Smart-in SM: Tensione di ingresso Tensione di ingresso POTENZA IN USCITA codice: codice: 400W SM-400 SM400-24 600W SM-600 SM600-24 1000W SM-1000 SM1000-24 1500W SM-1500 SM1500-24 Smart-in SP: Tensione di ingresso Tensione di ingresso POTENZA IN USCITA...
  • Page 21 di installare ed utilizzare gli inverter Smart-in SM e SP: ATTENZIONE! Fare molta attenzione nel maneggiare il dispositivo. Leggere questo manuale prima di procede con l'installazione e/o l'uso del dispositivo Il dispositivo è per un uso in ambiente chiuso, lontano da pioggia, spruzzi di acqua o liquidi vari L'introduzione di liquidi all'interno del dispositivo può...
  • Page 22: Protezioni

    4. PROTEZIONI: I nostri inverter sono equipaggiati con numerosi sistemi di proteizone per garantire la sicurezza: ✔ Avviamento senza brusche variazioni di corrente e tensione (Soft Start) ✔ Protezione da sovraccarico e cortocircuito ✔ Allarme per tensione batteria bassa ✔ Protezione contro l'inversione di polarità e sovratemperatura Allarme per tensione Avvisa se la batteria scende al di sotto di 10.5V o 21V.
  • Page 23: Funzionamento

    5. FUNZIONAMENTO: All'interno degli inverte Smart-in ci sono due circuiti principali che consentono la conversione della tensione continua in ingresso (DC) in tensione alternata in uscita (AC): 1) Il primo stadio del circuito è composto da un convertitore DC/DC ad alta frequenza con ingresso 12V (o 24V a seconde della versione) continui e uscita pari a circa 330V continui.
  • Page 24: Indicatori

    6. INDICATORI: Indicatori a LED Verde e Rosso: Il LED Verde è acceso quando l'inverter è operativo (ON) Il LED Rosso è acceso solo quando l'inverter è in condizione di allarme (sovracorrente, sovratemperatura ecc...) Interruttore principale a tre posizioni: 0 – Dispositivo spento 1 –...
  • Page 25: Possibili Interferenze

    7. POSSIBILI INTERFERENZE: Alcuni sistemi audio economici possono emettere un rumore dagli altoparlanti, quando sono alimentati mediante l'inverter. Questo dipende dal fatto che lo stadio di alimentazione del sistema non riesce a filtrare il segnale and onda modificata, quindi la soluzione possibile è quella di sostituire l'alimentatore del sistema audio o l'inverter con un uscita ad onda sinusoidale.
  • Page 26: Requisiti Delle Batterie

    8. REQUISITI DELLE BATTERIE: Il tipo di batteria e la capacità influenzano le prestazioni dell'inverter, perciò è necessario identificare il tipo di utenze che l'inverter deve alimentare e per quanto tempo. Per determinare la capacità minima della batteria da utilizzare, seguire i passaggi successivi: •...
  • Page 27: Montaggio Dell'inverter

    9. MONTAGGIO DELL'INVERTER: Gli inverter hanno delle flange o piedini in plastica per essere fissati. Il caso ideale è di installare il dispositivo su una superficie liscia e fredda (non su superfici rivestite con tessuto o moquette). Installare l'inverter più vicino possibile alle batterie a 12V o 24V a seconda della versione.
  • Page 28 Note: • Quando viene acceso l'inveter i due LED Verde e Rosso si accendono contemporaneamente per circa 3~5secondi poi il LED Rosso si spegne e quello Verde rimane acceso ad indicare che l'inverter è operativo, il Buzzer interno emette un beep all'accensione. Assicurarsi che la potenza complessiva delle utenze, non superi la potenza limite dell'inverter.
  • Page 29: Sostituzione Dei Fusibili

    Normalmente ricollegando bene la batteria e sostituendo i fusibili, l'inverter si riavvia automaticamente, però può succedere che ci siano dei guasti aggiuntivi per i quali è necessario contattare il servizio assistenza di NDS. OPZIONI: – E' disponibile un telecomando per il controllo remoto dell'inverter.
  • Page 30: Caratteristiche Tecniche

    13. CARATTERISTICHE TECNICHE: Smart-in Modified SM-400 SM400-24 Potenza di Uscita continua 400W 400W Potenza di Picco in Uscita 800W (pochi secondi) 800W (pochi secondi) Tensione di uscita (RMS) 110V or 230V 110V or 230V Frequenza in Uscita 50 or 60 Hz ± 3 Hz 50 or 60 Hz ±...
  • Page 31 Smart-in Pure SP-400 SP400-24 Potenza di Uscita continua 400W 400W Potenza di Picco in Uscita 1000W (pochi secondi) 1000W (pochi secondi) Tensione di uscita (RMS) 110V or 230V 110V or 230V Frequenza in Uscita 50 or 60 Hz ± 3 Hz 50 or 60 Hz ±...
  • Page 32: Garanzia

    Il certificato di garanzia ha validità solo se accompagnato da scontrino fiscale o documento di consegna. Per qualsiasi controversia sarà competente il Foro di Pescara. Mod..........Matricola..........Data acquisto ........Timbro e firma del rivenditore NDS ENERGY S.r.l. Via G. Pascoli, 169 65010 Cappelle sul Tavo (PE) Italy...