socomec DIRIS D-30 Instruction Manual

socomec DIRIS D-30 Instruction Manual

Control and power supply interface

Advertisement

Quick Links

DIRIS D-30
DIRIS Digiware
D-40
/
D-50
/
D-70
Control and power supply interface
EN
www.socomec.com/
en/diris-d

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DIRIS D-30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for socomec DIRIS D-30

  • Page 1 DIRIS D-30 DIRIS Digiware D-40 D-50 D-70 Control and power supply interface www.socomec.com/ en/diris-d...
  • Page 2: Table Of Contents

    CONTENTS 1. DOCUMENTATION ............2.
  • Page 3 ..........
  • Page 4: Documentation

    1. DOCUMENTATION www.socomec.com/en/diris-d...
  • Page 5: Hazards And Warnings

    2. HAZARDS AND WARNINGS professionals. 2.1. Risk of electrocution, burns or explosion Failure to take these precautions could cause death or serious injuries. 2.2. Risk of damaging the device Failure to respect these precautions could cause damage to the device. 2.3.
  • Page 6: Preliminary Operations

    3. PRELIMINARY OPERATIONS installation.
  • Page 7: Introduction

    4. INTRODUCTION 4.1. Range DIRIS D-30 DIRIS Digiware D-40 DIRIS Digiware D-50 DIRIS Digiware D-70 Single-point display Multipoint display Multipoint display Multipoint display 4.2. DIRIS D-30 DIRIS D-30...
  • Page 8: Introduction To Diris Digiware D

    4.3. Introduction to DIRIS Digiware D 4.3.1. DIRIS Digiware D-40 re D-40 4.3.2. DIRIS DIRIS Digiware D-50...
  • Page 9 4.3.3. network Consumption curves Load curves Measuring logs Logged data Compatible products Integration period 10 min to 60 min 1 min to 60 min Archiving period in D-70 Operation continues. Data backup Export to the FTP server Webview link Specific configuration automatically downloaded automatically downloaded...
  • Page 10 DIRIS DIRIS Digiware D-70...
  • Page 11: Touchscreens

    4.4. Touchscreens 4.5. LED display ALARM 4.6. Navigation LOADS MEASUREMENTS VOLTAGES EVENTS CURRENTS PHASE-PHASE LOAD PARAMETERS POWERS ..
  • Page 12: Menu Structure

    4.7. Menu structure D-30 D-40 D-50 Menu structure D-70 Load Voltages Currents Currents system Currents Measurements Current crest factor Powers Energies RESET all Min/Max values In progress Events History Language Date format Baudrate, stop, parity, address Display Baudrate, stop, parity, address DHCP, IP address, mask, gateway Activation - manual setting SNTP erver IP address, server port, time zone, Send settings)
  • Page 13: Dimensions

    4.8. Dimensions Dimensions in/mm 3.82 1.06 0.71...
  • Page 14: Mounting

    5. MOUNTING 5.1. Recommendations and safety 5.2. Back-plate mounting Dimensions in/mm 3 . 6 2...
  • Page 15: Connection

    6. CONNECTION 6.1. DIRIS D-30 - wiring DIRIS B DIRIS D-30 6.2. DIRIS Digiware D-40 - wiring Digiware LIYCY-CY SLAVE 24 VDC 24 VDC (20 W max) DIRIS Digiware D-40 re D-40 6.3. DIRIS Digiware D-50 / D-70 - wiring...
  • Page 16: Configuration

    7. CONFIGURATION HOME EVENTS HOME EVENTS...
  • Page 17: Specific Display Settings

    PARAMETERS … 7.1. PARAMETERS … 7.1.1. DISP PARAMETERS …...
  • Page 18: Language

    7.1.2. DISP PARAMETERS … 7.1.3. Language PARAMETERS … 7.1.4. Date format DATE FORMAT 7.1.5. RS485 communication...
  • Page 19 DIRIS Digiware D-50 / D-70 displays. PARAMETERS 7.1.6. Ethernet communication PARAMETERS 255.255.255.000 000.000.000.000 7.1.7. CONF. DATE/TIME TIME …...
  • Page 20 CONF. DATE/TIME SNTP 000.000.000.000 00123 DIRIS Digiware D display. 7.1.8.
  • Page 21 Read Community V1: Read-Write Community V1: Trap Community V1: alarm Read Community V2: Read-Write Community V2: D-70. Authentication protocol: Privacy Protocol: Read security username: Read authentication & privacy password: Read-Write security username: Read-Write authentication & privacy password:...
  • Page 22 Trap 1 server IP address: Trap 1 server port: Trap 2 server IP address: Trap 2 server port: Trap report frequency: set to 60min. www.socomec.com Activation: Virtual network ID:...
  • Page 23 Setting up the SMTP server Activation: SMTP server IP address or name: Security: SMTP Port: Secured port: Authentication: User name: Password: Email settings: Source Email Address:: Destination Email Address 1: Destination Email Address 2: Destination Email Address 3: Language: Criticality: Minimum send frequency time: FTP system: Planning:...
  • Page 24 FTP system Activation Activate FTP: Activate LOGS: Activate FTPS: Site ID and gateway ID: Files Destination folder: File format: software socomec. FTP server network settings Host: Port: Secured port: Login: enter your login Password: enter your password...
  • Page 25 Planning...
  • Page 26: Detecting And Addressing

    7.2. Detecting and addressing 7.2.1. Example of auto-addressing on the D-50 / D-70. address. D-50 / D-70 U-30 I-30 I-30 I-30 PARAMETERS … AUTODETECT...
  • Page 27 AUTODETECT AUTODETECT AUTODETECT AUTODETECT...
  • Page 28 AUTODETECT 3 sec. 3 sec. AUTODETECT...
  • Page 29 D-50 / D-70 U-30 I-30 I-30 I-30 LOAD1 PARAMETERS … LOAD1 LIST PROD. @003 @004 @005 @006...
  • Page 30: Diris Digiware

    7.2.2. 7.2.2.1. products. DIRIS Digiware D-40 D-40 U-30 I-30 I-30 I-30...
  • Page 31 DIRIS Digiware D-40 DIRIS G-xx D-40 U-30 I-30 I-30 I-30 DIRIS Digiware D-40 DIRIS Digiware D-40 DIRIS G-xx DIRIS G-xx D-40 D-40 D-40 D-40 U-30 U-30 U-30 U-30 I-30 I-30 I-30 I-30 I-30 I-30 I-30 I-30 I-30 I-30 I-30 I-30...
  • Page 32 DIRIS Digiware D-40 DIRIS G-xx D-40 D-40 U-30 U-30 I-30 I-30 I-30 I-30 I-30 I-30 DIRIS Digiware D-40 DIRIS G-xx DIRIS B-xx D-40 D-40 of a new product is already of an installed D-40. U-30 I-30 U-30 I-30 I-30 I-30 I-30 I-30...
  • Page 33 7.2.2.2. HOME EVENTS PARAMETERS … PARAM AFF … DIGIWARE ADDR DIGIWARE ADDR...
  • Page 34 DIGIWARE ADDR 7.2.2.3. products. Example of auto-addressing on the D-40. D-40 U-30 I-30 DIRIS Digiware D display. PARAMETERS …...
  • Page 35 AUTODETECT AUTODETECT AUTODETECT AUTODETECT...
  • Page 36 AUTODETECT AUTODETECT 3 sec. 3 sec. AUTODETECT...
  • Page 37 D-40 U-30 I-30 LOAD1 PARAMETERS … LOAD1 LIST PROD. @003 @004...
  • Page 38: Configuring Each Meter And Measuring Device

    7.3. LOAD1 PARAMETERS … Network: Load: LIST PROD. @004 @006 Diris U30 ID:546434 SELECT PROD.
  • Page 39: Network Configuration

    SELECT PROD.. @004 @006 Diris I30 ID:FOC1D2 SELECT PROD. 7.3.1. Diris U30 ID:546434 PARAMETERS 00400...
  • Page 40 7.3.2. Digiware display. 7.3.2.1. V1 V2 V3 VN Diris I30 ID:FOC1D2 OUTPUT LINES LINE V Diris I30 ID:FOC1D2 OUTPUT LINES LINE V...
  • Page 41 Diris I30 ID:FOC1D2 OUTPUT LINES LINE V Diris I30 ID:FOC1D2 OUTPUT LINES LINE V 7.3.2.2. Diris I30 ID:FOC1D2 OUTPUT LINES LINE V...
  • Page 42 LOAD 1 three-phase+neutral (3P+N) I1, I2, I3. Diris I30 ID:FOC1D2 PARAMETERS 00020 … Diris I30 ID:FOC1D2 PARAMETERS … 00020 … +/DIRECT Diris I30 ID:FOC1D2 CONFIG LINES LINE V 0600 DETECT...
  • Page 43 Diris I30 ID:FOC1D2 CONFIG LINES … … Diris I30 ID:FOC1D2 PARAMETERS 00020 … Diris I30 ID:FOC1D2 CONFIG LINES …...
  • Page 44: Use

    8. USE HOME EVENTS...
  • Page 45: Snmp Communication With The Diris Digiware

    9. SNMP COMMUNICATION WITH THE DIRIS DIGIWARE D-70 9.1. SNMP generalities Common SNMP terms Consumption curves Agent Managed device Community strings Traps 9.2. SNMP functions supported GetRequest: GetNextRequest: GetBulk: SetRequest: Traps:...
  • Page 46: Snmp Versions Supported

    9.3. SNMP versions supported SNMPv1 and v2: SNMPv3:...
  • Page 47: Snmp Ports

    9.5. Root iso (1) org (3) dod (6) Internet (1) directory (1) mgm (2) experimental (3) private (4) mib-2 (1) enterprise (1) system (1) interfaces (2) ip (4) vendor X (2) vendor Y (9) SOCOMEC (4555) OID Tree Example 1.3.6.1.4.1.4555.
  • Page 48 4555.10.20.20.1.10000. OID sequence Description 4555 10000 To identify those multiple devices, the Modbus address and the load number are added to the end of the OID. D-50 D-50 Product I-30 I-30 Modbus address Load type U-30 I-30 I-30 1.3.6.1.4.1.4555.10.20.1.10000.4.1 1.3.6.1.4.1.4555.10.20.1.10000.5.1 1.3.6.1.4.1.4555.10.20.1.10000.5.2 1.3.6.1.4.1.4555.10.20.1.10000.5.3 OID sequence...
  • Page 49: Bacnet Communication With The Diris Digiware

    10. BACNET COMMUNICATION WITH THE DIRIS DIGIWARE D-70 www.socomec.com. 10.1. BACnet Generalities Object: Property: Present value: Service: 10.2. BACnet Objects Object type Exemple of use...
  • Page 50 Device Object: Property BACnet System_Status Class Supported Supported Supported Segmentation_Supported Location Description Local_Date...
  • Page 51 Analog Input Object: Property BACnet Units Description...
  • Page 52 Unsigned Unsigned CurrentSyst System Current Unsigned System Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned...
  • Page 53 Unsigned CurrentI1 Current I1 Unsigned CurrentI2 Current I2 Unsigned CurrentI3 Current I3 Unsigned CurrentIn Current In Unsigned Unsigned CurrentIdir Current Idir Unsigned Unsigned Unsigned Unsigned Nominal Unsigned Signed Signed Unsigned Signed Unsigned Signed Signed Signed Signed Signed Signed Unsigned Unsigned Unsigned Signed Unsigned...
  • Page 54 Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Unsigned Signed 10.3. BACnet Services Service list Description...
  • Page 55: Characteristics

    11. CHARACTERISTICS 11.1. DIRIS D-30 and DIRIS Digiware D-40/D-50/D-70 - characteristics 11.1.1. Mechanical features Screen resolution 50/D-70 11.1.2. Self-powered and data 11.1.3. RJ45 Digiware Control and power supply interface function 11.1.4. RJ45 Digiware Control and power supply interface function 11.1.5.
  • Page 56 11.1.6. Electrical characteristics 3 days 11.1.7. Storage temperature Installation category - degree of pollution...
  • Page 58 CORPORATE HQ CONTACT: SOCOMEC SAS 1-4 RUE DE WESTHOUSE 67235 BENFELD, FRANCE www.socomec.com...

Table of Contents