Cable Specification - ALLIANCE ALLPH35R410 Installation & Operation Manual

Swimming pool heat pump
Table of Contents

Advertisement

6. A P P E N D I X

6.2 Cable specification

NAME PLATE
MAXIMUM
PHASE LINE
CURRENT
No more than 10A
10~16A
16~25A
25~32A
32~4QA
40~63A
63~75A
75~1Q1A
101~123A
123~148A
148~186A
186~224A
NAME PLATE
MAXIMUM
PHASE LINE
CURRENT
No more than 10A
10~16A
16~25A
25~32A
32~4QA
40~63A
63~75A
75~1Q1A
101~123A
123~148A
148~186A
186~224A
If the unit is installed outdoors, please use a UV protected cable.
1. SINGLE PHASE UNIT
EARTH LINE
2 X 1.5mm
1.5mm
2
2 X 2.5mm
2.5mm
2
2 X 4mm
4mm
2
2 X 6mm
6mm
2
2 X 10mm
10mm
2
2 X 16mm
2
16mm
2 X 25mm
25mm
2
2 X 25mm
2
25mm
2 X 35mm
35mm
2
2 X 50mm
50mm
2
2 X 70mm
70mm
2
2 X 95mm
95mm
2
2. THREE PHASE UNIT
EARTH LINE
3 X 1.5mm
1.5mm
2
3 X 2.5mm
2.5mm
2
3 X 4mm
4mm
2
3 X 6mm
6mm
2
3 X 10mm
10mm
2
3 X 16mm
2
16mm
3 X 25mm
25mm
2
3 X 25mm
25mm
2
3 X 35mm
35mm
2
3 X 50mm
50mm
2
3 X 70mm
70mm
2
3 X 95mm
95mm
2
MCB
CREEPAGE PROTECTOR
20A 30mA less than 0.1 sec
2
32A 30mA less than 0.1 sec
2
40A 30mA less than 0.1 sec
2
40A 30mA less than 0.1 sec
2
63A 30mA less than 0.1 sec
2
2
80A 30mA less than 0.1 sec
100A 30mA less than 0.1 sec
2
2
125A 30mA less than 0.1 sec
160A 30mA less than 0.1 sec
2
225A 30mA less than 0.1 sec
2
250A 30mA less than 0.1 sec
2
280A 30mA less than 0.1 sec
2
MCB
CREEPAGE PROTECTOR
20A 30mA less than 0.1 sec
2
32A 30mA less than 0.1 sec
2
40A 30mA less than 0.1 sec
2
40A 30mA less than 0.1 sec
2
63A 30mA less than 0.1 sec
2
2
80A 30mA less than 0.1 sec
100A 30mA less than 0.1 sec
2
125A 30mA less than 0.1 sec
2
160A 30mA less than 0.1 sec
2
225A 30mA less than 0.1 sec
2
250A 30mA less than 0.1 sec
2
280A 30mA less than 0.1 sec
2
SIGNAL LINE
n X 0.5mm
2
SIGNAL LINE
n X 0.5mm
2
21