Appendix; Connection Of Pcb Llustration - ALLIANCE ALLPH35R410 Installation & Operation Manual

Swimming pool heat pump
Table of Contents

Advertisement

6. A P P E N D I X
6.1 Connection of PCB illustration
CONNECTIONS EXPLANATION:
#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
SYMBOL
MEANING
OUT1
Compressor of system 1 (220-230VAC)
OUT2
Water pump (220-230VAC)
OUT3
4way valve (220-230VAC)
OUT4
High speed fan motor (220-230VAC)
OUT5
Low speed fan motor (220-230VAC)
AC-N
Neutral wire
NET GND 12V
Wire controller
DI01 GND
On/Off Switch(input)
DI02 GND
Flow switch (input)( normal close)
DI03 GND
Low pressure protect
DI04 GND
High pressure protect
DI05 GND
Not used
DI06 GND
Not used
AI01 GND
Suction temp.(input)
AI02 GND
Water in temp.(input)
AI03 GND
Water out temp.(input)
AI04 GND
Temp. Of coil (input)
AI05 GND
Ambient temp.(input)
AI06 GND
No use
CN1
Primary transformer
CN2
Secondary transformer
CN6
Not used
CN19
Electronic expansion valve
5V CN16 GNC
Flow meter
ê
20

Advertisement

Table of Contents
loading

Table of Contents