Mira SELECT Installation & User Manual page 19

Thermostatic mixer
Hide thumbs Also See for SELECT:
Table of Contents

Advertisement

Screw
Retaining Ring
22. Check that the blue 'O' seal is fitted inside the
backplate nut. Fit the olive and the backplate
nut over the outlet pipe, do not tighten the nut
fully at this point.
23. To prevent the backplate from turning while
tightening the nut, fit the retaining ring over the
backplate nut making sure the slots engage
with the screws on the backplate, hold the
retaining ring with a wrench while tightening
the backplate nut. Remove the retaining ring
after use.
24. Check that the second 'O' seal (black) is fitted
to the outside of the backplate nut. Press the
elbow onto the backplate, make sure that the
clips on the elbow engage with the backplate.
25. Slide the retaining ring over the elbow and
engage with the elbow clips. Note! The
retaining ring must be engaged correctly to
lock the elbow to the backplate, rotate the
retaining ring to the postition illustrated.
Olive
Backplate Nut
Slot
Elbow
26. Press the shroud over the elbow, make sure
that it engages with the lugs on the backplate.
27. This completes the installation of the RAC
assembly, fit the concealing plate and
control assembly. Refer to section: 'Control
Assembly'.
Mira Select RAC:
1. Before the RAC assembly can be fitted you
must have first installed your built-in shower
control and have connected the inlet and outlet
pipework.
Important! Make sure that the outlet pipework
is securely fixed and that you leave enough
pipe to connect a 1/2" BSP female fitting (not
supplied) to the RAC assembly.
2. Apply liquid sealant or PTFE tape (do not use
paste) to the brass nipple and screw into the
1/2" BSP female fitting (not supplied).
Important! For stud partition installations
screw a backnut (not supplied) on the rear of
the brass nipple.
Finished Wall Surface
20 - 22 mm
Solid or Dry
Lined Walls
3. Temporarily cap off the brass nipple, turn on
the water supplies and check for leaks.
19
Retaining Ring shown
correctly engaged with
Elbow
1
2
Backnut (not
supplied)
20 - 22 mm
1/2" BSP Female
Fitting (not supplied)
Laminated Panel or
Stud Partition Walls

Advertisement

Table of Contents
loading