9. Mark the positions of the two RAC backplate
fixing holes and drill two Ø5.5 mm holes.
Caution! Make sure that you do not drill into
pipework in the wall.
10. Hold the RAC wallplate in position on the rear
of the partition, insert the two backplate screws
and secure the RAC backplate to the wallplate.
Make sure that the foam seal abuts the finished
wall surface. Go to instruction 22.
11. Loosely attach the RAC backplate to the RAC
wallplate, using the two backplate screws
provided.
12. Place the RAC backplate/wallplate assembly
over the outlet pipe with the arrow pointing
vertically up. The screw holes should be at
40° to the horizontal.
13. Mark the positions of the two RAC wallplate
fixing holes.
Wallplate
40°
RAC Backplate
Backplate Screws
14. Remove the assembly from the wall and
separate the backplate from the wallplate.
15. For solid walls drill two Ø6 mm holes for the
wall plugs. For other types of wall structure
alternative fixings may be required (not
supplied). If necessary, make a recess 6 mm
deep to accept the wallplate for flush fitting of
the outlet to the wall surface.
Caution! Make sure that you do not drill into
pipework in the wall.
RAC Backplate
Backplate
Screws
Arrow
16. Fit the two wall plugs supplied and secure
the wallplate to the wall with the two wallplate
screws.
17. Make sure that there is clearance behind the
wallplate and temporarily fit the two backplate
screws into the wallplate. This will prevent
the fixing holes from becoming blocked with
plaster or grout.
18. Secure the building-in shroud to the mixing
valve using the two shroud screws removed
earlier.
19. Using the building-in shroud as a guide, finish
the wall, e.g. tiles.
Caution! Make sure that the finished wall is
within the maximum and minimum limits and to
an even depth (no greater than 2 mm variation)
or the control components will not fit correctly.
Min Finished
Wall Surface
Max Finished
Wall Surface
20.Remove the two backplate screws, the two
building-in shroud screws (retain for later
use) and the building-in shroud.
21. Place the backplate over the outlet pipe with
the arrow pointing vertically up and tighten the
two backplate screws. Make sure that the foam
seal abuts the finished wall surface.