Mira SELECT Installation & User Manual page 15

Thermostatic mixer
Hide thumbs Also See for SELECT:
Table of Contents

Advertisement

3. Laminated Panel
(Using Securing Brackets - Mount-
ing on Rear Face of Wall)
Note! For laminated panels the mixing valve must
be positioned from the rear of the panel.
Panel thickness must be between 4 and 12 mm.
(If a thicker panel is used, it will be necessary
to recess the securing brackets into the rear of
the panel.)
Important! Make sure that there is a minimum
clearance of 64 mm behind the laminated panel
to accommodate the mixing valve.
1. Remove the two shroud screws (retain for later
use) and separate the mixing valve from the
building-in shroud.
2. Mark the position of the mixing valve using the
building-in shroud as a guide.
3. Carefully cut out the laminated panel.
4. Secure the securing brackets to the mixing
valve with the bracket screws.
Important! The securing brackets must be
fixed vertically, as illustrated.
Important! Make sure that the correct holes
are used, otherwise the backplate cannot be
fitted.
Backplate
Securing Hole
5. Position the mixing valve on the front of the
panel, make sure that it is level and central
Shroud
in the hole, then mark the position of the M5
Screws
fixing holes.
(retain for
Important! Make sure that the correct holes
later use)
are used (refer to illustration).
Note! Make sure that the filter plugs are
positioned so that they can be removed for
servicing.
6. Drill the two Ø5.5 mm holes for the fixing
positions (countersink the holes at the front).
7. Secure the mixing valve on the rear of
the panel with the M5 x 40 mm screws as
shown.
15
M5 Fixing Hole
Backplate Securing
Hole
Filter Plug
M5 Fixing
Hole
M5 x 40 mm
Fixing Screws

Advertisement