CHAPTER 12
Art-Net™ Protocol
Note:
Consult your manufacturers instruction manual for the correct IP
settings, which may be different to the ones described.
The default IP address setting
is 2.0.0.x, where x is an integer
value from 0 - 255. Some
ArtNet boxes can use an
alternative IP address, which is
10.0.0.x. The Subnet Mask for
Artnet is 255.0.0.y, where y is
the position of the SubNet
switch on your Artnet
interface. Generally, this would
be set to zero.
Once you have entered your IP
and Subnet settings, click the
Apply Now button to apply the
changes.
Sometimes it may be necessary
to configure the network speed.
Artnet is a 10base T protocol,
and Macintosh computers can
support 10base T, 100base T
and Gigabit Ethernet.
4.
Use the Apply Now button to
apply the changes to your
Ethernet settings.
Artnet status can be monitored in
the ArtNet Diagnostic screen.
120