Fronius IG Installation

General

IMPORTANT! Depending on the surface, different wall anchors and screws may be re-
quired for installing the wall bracket. These wall anchors and screws are not part of the
scope of delivery for the inverter. The installer is responsible for selecting the proper wall
anchors and screws.
Recommended
In most cases, you should use 1/4 in. or 5/16 in. stainless steel or aluminum screws capa-
screws for
ble of supporting:
mounting plate
-
assembly
-
Attaching the
IMPORTANT! Keep a minimum distance under the inverter corresponding to the 'NEC
mounting plate -
110.26 for code compliant disconnect location. If the DC disconnect is to be code compli-
mounting height
ant, it must be readily accessible (NEC 690.14 (B) (1)).
The DC disconnect is in the lower left part of the inverter. When choosing the inverter
mounting height, ensure a height that keeps the display slightly below eye level for best
possible readability of the display.
NOTE! The inverter is designed only for a vertical installation position.
26 lbs. for Fronius IG 2000 / 3000 / 2500-LV
42 lbs. for Fronius IG 4000 / 5000 / 4500-LV