Menu Map - Gecko Compact Product User Manual

Seismographs, accelerographs recorders, vibration monitors
Hide thumbs Also See for Compact:
Table of Contents

Advertisement

Menu Map

After start-up, pressing the Menu button will toggle between the main menu and the home
screen. The LCD backlight will stay on for 2 minutes from the last button press.
On most screens you can scroll Up and Down through a list and enter a menu item or
toggle a setting by using the Right button. Pressing the Menu button will save the current
setting and take you back one menu level.
E:
-2,726
0.6
N:
4,326
0.8
Z:
-698
0.7
O:
12,356
1.2
p
3D
0.1234567 mm/s
max
11.1234567 mm/s
1D
80.2123546 dB
max 101.1234567 dB
p
2019-04-01
11:52:18
E:
-0.0439408 mm/s
N:
0.0360011 mm/s
Z:
-0.0011021 mm/s
p
Home Screen
2019-04-01
11:52:16
GECKO
Storing ENZO+
GPS:04 Sending ___O+
32GB
free:92.23495%
Main Menu
Unmount SD card
> Station Info
Sample Rate
Channels to Store
Channels to Send
3D Sensor
1D Sensor
Input Amplifier
Trigger & Alarm
Telemetry
Settings File
Start Calibration
Communications
> Mode: Continuous
Device: 3G modem
TCP Socket Port
Server IP/Domain
Carrier APN
Gecko menu appearance will vary by model:
*1 will not appear on 3-channel models
*1
*2 "1D Sensor Info" will show here for 4-channel models
*3 will only appear on Gecko Compact & Rugged
*1
*4 will only appear if sensor has calibration function
*1
*5 will not appear when setting up 4th channel
*6 will only appear for 3G modem on menu re-entry
Info & Telemetry
Volt: 14.06
500sps
u
Temp: 35.5°
#2000343
v4.2.4271
Connected to Server
Station Information
Station Code
> Network Code
Location ID (3D)
Location ID (1D)
*3
3D Sensor
*1
> Select a Sensor
Sensor Serial No
Mass Lock
Mass Unlock
*4
Trigger & Alarm
> Level
STA/LTA
*6
*6
Alarm Outputs
*6
System Alerts
3D Sensor Info
3D Sensor Name & S/N
x512
u
Gecko Blast
586-H2 586-H1 586-V3
Type: Acceleration
Save Continuous Data
Channel E: On
Channel N: On
Channel Z: On
*1
Channel O: On
3D Vector: Off
Select a Sensor
Custom Sensor
> Geophone 28.8V/m/s
Geospace GS-1 1Hz
*5
...<more>
*5
*5
STA/LTA Triggering
Enable: Off
> Threshold
STA window size
LTA window size
Filter:
2-20Hz
Channel: Z+N+E
3
GPS location information
Lat: -37.8189800
*2
u
Long: 145.0109620
Sats: 12
Alt:
22m
hAcc: 10m
vAcc: 19m
3D Sensor
Sensor Name
> Units
Sensitivity ch E
*1
Sensitivity ch N
Sensitivity ch Z
Auto-Zero Delay
Cal Enable
Cal Type
Cal Duration
Cal Sine Freq
SIG+ Mode: Normal
SIG- Mode: Normal
Input: DC Offset
Level Triggering
> Enable: Off
Set Trigger Level
*5
*5
*5
*5
*5
*5
*5
*5
*5
*5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

TremorPrismRuggedSmaSma-hrBlast

Table of Contents