6.1.1 Function
No function / M-Stop – Start/Stop of the device
via external control signal.
With  and  you make a choice according to
the display. With C you quit the menu point
without any change and with  the input is ac-
cepted and you quit the menu level.
6.1.2 Effect direction
Direct / inverted
With  and  you make a choice according to
the display. With C you quit the menu point
without any change and with  the input is ac-
cepted and you quit the menu level.
6.1.3 Filter
Dead time after activating (for debouncing of me-
chanical switching contacts).
Range of 0...99,9 s
With C you set the value to 0.0. With the num-
bers you input the beginning value and with 
the input is accepted and you quit the menu level.
6.2 Digital input 2
Analogue to digital input 1
7 System
Setting of the Mod-bus interface parameters when
connecting to the system bus.
With  and  you make a choice according to
the display. With C you quit the menu point
without any change and with  the input is accepted and you arrive 1 menu point
lower to make your settings.
7.1 Baud rate
Choice of baud rate between 4800 / 9600 / 19200 /
38400
With  and  you make a choice according to
the display. With C you quit the menu point
without any change and with  the input is accepted and you quit the menu level.
Digital input 1
Function
none
Dig. input 1
Effect direction
direct
Dig. input1
7
8
Filter
4
5
1.0
s
1
2
C
0
7.System
7.1.Baud rate
9600
7.2.Address
1
7.3.Contrast
7.3.Language
D
System
Baud rate
9600
C
C
9
6
3
C